8.3
Adjustment of Levelling Feet
Type: All models in the series, except for TT20Bazic / TT20Streamline
There are installed/can be installed levelling feet under the stove. Levelling feet are used if the floor is uneven or if you want an
optical "floating" stove, or if you want to use a custom-cut floor plate. Alternatively, you can let the stove stand on the base plate.
If a custom-cut floor plate is used, the levelling feet should be installed/used/adjusted for this purpose. Otherwise, the custom-cut
floor plate cannot be installed. Note that all specified measurements (on the stove) are without levelling feet. If you use levelling
feet, the stove will be correspondingly higher.
8.4
Setting up the Wood Stove (Continuation of Levelling Feet)
Type: Alle models in the TT21 series
The stove comes with a plastic bag containing the following items: 1=Plug (1 piece), 2=Dowel screws (4 pieces), 3=Floor protector
(2 pieces) (see Fig. 1).
If levelling feet are not used or if the stove is stable on the levelling feet, insert the plug (1) into the hole in the front (Fig. 2).
If the levelling feet are used and the stove is not completely stable (tilting when the door is opened), follow these steps: In the
base plate's 2 threaded holes, one in the front (Fig. 2) and one at the rear (Fig. 3), mount a dowel screw of suitable length, as
indicated by the blue arrow (Fig. 5+6).
To access the rear threaded hole, remove the lower cover plate on the back panel (Fig. 3). The floor protector, indicated by the
white arrow (Fig. 5+6), is gently inserted under the base plate of the stove and positioned directly under the dowel screw. Then,
adjust the dowel screw appropriately downwards, so it makes contact with the floor protector, ensuring the stove stands stable.
The same procedure is followed for the rear threaded hole in the base plate (Fig. 3+5).
Fig. 1
TermaTech A/S, Gunnar Clausens Vej 36, DK-8260 Viby J
The four hexagonal levelling feet are installed in the four threaded holes on the
base plate. Refer to the white arrows. The levelling feet are adjusted with your
fingers or a 25mm open-end wrench so that there is a distance of approximately
8mm between the base plate and the floor, depending on the choice of floor
plate.
Fig. 2
www.termatech.com
Fig. 3
21-12-2023 LP
Item no. 99-274
45