Test Leads
CAT IV 600V
CAT III 1000V
OPERATION:
High Voltage Warning (HI-V)
The meter beeps and lights an LED when measuring > 30V AC on the VAC function and >30V DC
when on the VDC function.
Notes: This feature does not work in the Ohm, capacitor, continuity or clamp modes. Audible indica-
tion can be disabled by pressing and holding the Max/min button while turning the function switch
from OFF to any desired Function. Wait for Hb to be displayed and then release the button. To
enable, turn the unit off and back on.
Data Hold Feature
Press the Hold button on the side of the meter to toggle in and out of the data hold mode. "HOLD"
appears in the upper left of the meter display when data hold is active. Use the data hold feature to
lock a measurement reading on the display. Press the Hold button again to unlock the display and
obtain a real-time reading.
Peak Feature
In PEAK mode, the meter displayed the PEAK value of AC Volts or Current measurement.
PEAK function is enabled by Depressing the PEAK HOLD button for > 2 seconds.
To Exit PEAK Mode Depress the PEAK HOLD button again for > 2 seconds.
Max/Min Feature
The Max/Min records the maximum and minimum measured value. Press the Max/Min button to
activate this feature and to toggle between max, and Min readings. The unit will continually capture
max and min values over time. Depressing the max/min button for >2 sec. exits the mode. Note:
To record max/min values over a time period >30 min, the Auto Power Off (APO) feature must be
defeated.
Relative Mode
Press "∆" button to enter the Relative mode. The "∆" symbol is displayed, and the value on
the display is subtracted and stored as a reference value. In the Relative mode, the value shown
on the display is always the difference between the stored reference value and the present
reading. Press the "∆" button again for > 2 seconds to exit the Relative mode.
Zero Feature (61-765, 61-775 models only)
The "ZERO" button is used to zero out the display before measuring DC current. Press the
"ZERO" button to subtract out the non-zero number. Then, measure the DC amps. Pressing the
"ZERO" button again causes the "ZERO" to flash and the original offset number to be displayed.
Depress the "ZERO" button for >2 sec. to exit this mode.