Storing flammable or hazardous liquids in the cabinet is strictly prohibited.
2.3. Package
Transport or move the cabinet to its destination site in the original factory packing, whenever
possible. The packaging materials are recyclable.
NOTE
(This applies to cabinets using R290 as refrigerant): do not turn on the power to
the cabinet if you suspect that a refrigerant leakage has occurred during
transportation.
2.4. Transport damage
Unpack the cabinet and check for any sign of damage during transport. Report any damage
immediately to your insurance company, or to the supplier or manufacturer of the cabinet.
2.5. Installing
1. Release the tape from the air gap stopper and let it fall into a horizontal position.
2. Set the cabinet in its place.
Leave an unobstructed air gap of at least 8 cm behind
the cabinet, also when cabinets are back to back,
and of at least 25 cm above the cabinet.
3. Adjust the cabinet to stand perpendicularly using the
adjustable legs.
Version 2/2013
All manuals and user guides at all-guides.com
ENGLISH
4