Press the lower button to confirm
N
that the fault memory should be
cleared.
Insert adapter,
Switch on the saw.
Insert the adapter in the cordless
N
power tool.
Switch on the cordless power tool –
N
see power tool's instruction manual.
Fault memory is cleared. To avoid
damage to the electronic module, the
adapter must not be removed from the
cordless power tool and the battery must
not be removed from the analyzer while
the memory is being cleared.
Do not remove unit
On completion, the analyzer's display
confirms that the memory has been
cleared.
Memory cleared
End of test
The test is restarted by pressing the
lower button.
After the test
Remove the battery from the
N
analyzer.
When the battery is removed, the data of
the cordless power tool that has been
tested is deleted from the analyzer. The
analyzer can then be used to test further
cordless power tools.
ADG 2
Light Emitting Diodes (LED)
on Battery
Four light emitting diodes indicate the
condition of the battery.
1
Press button (1) to activate the
N
display – the display goes off
automatically after 5 seconds.
The light emitting diodes can glow or
flash green or red.
Light emitting diode glows con -
tinuously green.
Light emitting diode flashes
green.
Light emitting diode glows con -
tinuously red.
Light emitting diode flashes red.
If the green light emitting diodes glow /
flash
80 - 100 %
60 - 80 %
40 - 60 %
20 - 40 %
0 - 20 %
The green light emitting diodes indicate
the battery's state of charge by glowing
and flashing continuously.
English
7