Measuring Voltage:
• Slide the function switch to the Volt position.
Note: The measurement mode defaults to AC voltage.
• If measuring DC voltage, use the AC/DC button to toggle to DC voltage. The meter
display will confirm the active mode (AC or DC) on the left side of the display.
• Hold the test leads behind the finger guards and apply the lead tips in parallel
to the circuit under test.
• The meter will sense the level of voltage, automatically range to obtain the best
resolution, and accurately display the measurement.
Note: To measure millivolts, use "RANGE" button to manually select mV range.
CAUTION: For maximum safety, do not hold the meter in your hands
while measuring higher voltages.
If the meter displays zero or low volts, ensure that the meter is prop-
erly set to measure AC or DC volts and verify on a known live source.
Measuring Resistance (Ohms):
• Verify the circuit is de-energized to obtain accurate measurements.
• Slide the function switch to the Ω/
Note: The measurement mode defaults to Ohms (Ω).
• Hold the test leads behind the finger guards and apply the lead tips to the
component or circuit under test.
• The meter will sense the level of resistance, automatically range to obtain the best
resolution, and accurately display the measurement.
Verifying Continuity (
• Verify the circuit is de-energized.
• Slide the function switch to the Ω/
Note: The measurement mode defaults to Ohms (Ω).
• Press the Ω/
should show the
• Hold the test leads behind the finger guards and apply the lead tips to the
component or circuit under test.
• The meter will sense the level of resistance and beep if the resistance is less
than 25 Ω to confirm that continuity is present.
/
):
/
button once to toggle to Continuity. The meter display
/
in the upper right corner.
/
position.
/
position.
4