Application
Operation is possible in conjunction with:
• Pressurized storage heaters
Operation is not possible with:
• Low-pressure storage heaters (displacement water heaters)
Specifications
• Max. flow
EcoJoy
• Flow pressure
- min.
- recommended
- greater than 72.5 psi, fit pressure reducing valve
• Max. operating pressure
• Test pressure
• Temperature
- max. (hot water inlet)
Scalding protection possible by fitting a handle rotation stop
(order no. 46 375).
• Water connection:
• Deck thickness max.
• Non reversible cartridge
Notes:
- Major pressure differences between cold and hot water supply
should be avoided.
- To be installed according to local codes and regulations.
- This faucet is not intended for the use with portable appliances.
Installation
Flush piping system prior and after installation of faucet
thoroughly!
Mount sink faucet, see fold-out page II, fig. [1].
Refer to the dimensional drawing on fold-out page I.
Note:
If brace (A) is omitted, deck thickness can be increased by 9/16" to
a total of 2 3/8".
Connect sink faucet, see figs. [1] and [2].
- Cold water connection (marked blue) = right
- Hot water connection (marked red)
Avoid cross connection. The cartridge is not reversible.
Connect the spray hose (B), see fig. [3].
1. Connect the handspray (C) without using any additional seals.
2. Fit one side of the stop (D) and spring (E) over the spray
hose (B) from below.
3. Pass the end of the spray hose (B) through the other hole in the
stop (D).
4. Install the snap coupling (G) on the end of the spray hose (B) and
tighten by hand.
5. Push the sleeve (J) of the snap coupling (G) downwards and fit
the coupling to the union (K).
To ensure that the handspray (C) is correctly seated when inserted,
lug (L) on the outlet must engage in recess on the handspray (M).
Open cold and hot-water supply and check connections for
leakage!
1
English
Operation
Lift lever
Press lever down
Move lever to right
Move lever to left
Flow rate limiter
This faucet is fitted out with a flow rate limiter, permitting an
infinitely individual variable reduction of the flow rate. The highest
8.3 L/min or 2.2 gpm/60 psi
possible flow rate is set by the plant before despatch.
5.7 L/min or 1.5 gpm/60 psi
The use of flow rate limiters in combination with hydraulic
instantaneous water heaters is not recommended.
7.25 psi
To activate see "Replacing the cartridge" point 1 to 4,
14.5 - 72.5 psi
figs. [4] and [5].
145 psi
232 psi
176 °F
Maintenance
Inspect and clean all parts, replace as necessary and grease with
cold - RH
hot - LH
special grease.
2 3/8"
Shut off cold and hot water supply!
I. Replacing the cartridge, see fold-out page II, fig. [4].
1. Lever out plug (N).
2. Remove set screw (O) using an 3mm allen wrench and pull off
lever (P).
3. Pull off cap (T).
4. Turn out screwing (U) with key 32mm.
5. Change complete cartridge (V).
Assemble in reverse order.
Observe the correct installation position!
Make sure that the cartridge seals engage in the grooves and the
locating pins at the base of the cartridge slot into the apertures on
the housing.
Screw in and tighten screwing (U).
II. Cleaning the aerator, see fold-out page I.
Unscrew and clean aerator.
Replacement parts, see fold-out page I ( * = special accessories).
= left
Care
Instructions for care of this faucet will be found in the Limited
Warranty supplement.
= open (water flow)
= closed (off)
= cold water
= hot water

Publicité

loading