Télécharger Imprimer la page

Powermate PM3000i Manuel Du Propriétaire page 10

Publicité

Les langues disponibles

Les langues disponibles

Circuit Protectors
The AC receptacles are protected by an AC
circuit protector. If the generator is overloaded
or an external short circuit occurs, the circuit
protector will trip. If this occurs, disconnect all
electrical loads to determine the cause of the
problem before using the generator again.
Reduce the load if the circuit protector is
tripped.
NOTE: Continuous tripping of the circuit pro-
tector may cause damage to generator or
equipment.
Push the button of the protector to reset the
circuit protector.
Remove Contents from Carton
1. Open carton completely by cutting each
corner from top to bottom.
2. Remove and verify carton contents prior to
assembly. Carton contents should contain
the following:
Accessories
Item
Main Unit
Owner's Manual
Engine Oil
Oil Funnel
Tool Kit
Service Warranty
Emissions Warranty
3. Call Powermate Customer Service at 1-
800-445-1805 with the unit model and
serial number for any missing carton con-
tents.
4. Record model, serial number, and date of
purchase on front cover of this manual.
Add Engine Oil
Engine damage. Verify proper type and quantity of
engine oil prior to starting engine. Failure to do so
could result in engine damage.
NOTE: The generator is shipped without oil in
the engine. Add oil slowly and verify oil level
often during filling process to ensure overfilling
does not occur.
1. Place generator on a level surface.
2. Remove screws and side cover.
3. Verify oil fill area is clean.
4. See
2-9. Remove oil fill cap/dipstick
Figure
and wipe dipstick clean.
8
CAUTION
(000135)
5. Insert funnel into oil fill opening. Add rec-
ommended engine oil as necessary. Cli-
mate
viscosity. See chart below to select correct
viscosity.
NOTE: Use petroleum based oil (supplied) for
engine break-in before using synthetic oil.
Qty.
1
1
1
1
1
6. See
Figure
1
funnel and insert dipstick into oil filler neck
without screwing it in.
1
Figure 2-10. Safe Operating Range
7. Remove dipstick and verify oil level is
within safe operating range.
NOTE: Verify oil level often during filling pro-
cess to ensure overfilling does not occur.
8. Install oil fill cap/dipstick and hand-tighten.
9. Install side panel and screws.
Figure 2-9. Remove Dipstick
determines
proper
10W-30
Synthetic 5W-30
2-10. To check oil level, remove
Owner's Manual for Portable Generator
000115
engine
oil
SAE 30
000399
005484