so, take the pump to your supplier or to an accredited professional to open the
device and remove the residue.
 If you regularly use the pump at different locations, you must rinse with clean
water (inside and out) after each use.
 Keep the base of the well (or the tile on which the pump is positioned) free from
mud and residue.
 Ensure that the pump does not freeze. Before winter sets in, run the pump dry
and store it in a frost-free location.
DEFECTS – CAUSES – SOLUTIONS
Defects
Pump does not start
Pump runs but does
not pump water
Insufficient water
Pump does not start or
suddenly switches off
while functioning
Pump does not start
and stop in AUTO
setting
If these tips do not provide a solution, contact your supplier or service point.
Causes
No electricity
-
Overheating safeguard
-
activated
-
Pump is stuck
-
Inlet openings are clogged
-
Water drainage pipe is bent or
hose is blocked
Air around the blade
-
-
Blade is jammed
-
Water level is too low (manual
usage)
-
CW: return valve in pump
outlet is blocked
Inlet openings are (partially)
-
blocked
Outlet drain (partially) blocked
-
Broken fan
-
Thermal safeguard stops pump
-
due to overheating
Water is too hot
-
-
Power outage
Dirt or stones in the water
-
supply
Blade is stuck
-
-
Problem with the motor
Pump is not vertical
-
-
The float is stuck
15
Solutions
Check electrical supply
-
See: overheating safeguard.
-
-
Clean float and float axle
-
Clean them
-
Straighten the hose or remove the
blockage
Switch the pump off and move it from
-
side to side. Wait until the air has
escaped and switch on again
-
Try to remove the blockage or ask a
professional to do so
Submerge the pump in deeper water
-
-
Remove blockage
Clean them
-
Remove blockage
-
Replace the fan
-
See: overheating safeguard
-
Max. water temperature 35°C
-
-
Check fuses and earth leakage
Remove dirt and stones
-
-
Remove blockage if possible or
consult service point
Consult service point
-
Make sure the pump is standing up
-
straight
Clean the float
-