All manuals and user guides at all-guides.com
Dear buyer, we thank you for purchase of our product.
PRIOR TO INSTALATION AND FIRST USE, PLEASE CAREFULLY
READ THESE INSTRUCTIONS.
This water heater has been manufactured in compliance with the relevant standards and test-
ed by the relevant authorities as indicated by the Safety Certificate and the Electromagnetic
Compatibility Certificate. The technical characteristics of the product are listed on the label
affixed between the inlet and outlet pipes. The installation must be carried out by qualified staff.
All repairs and maintenance work within the water heater, e.g. lime removal or
inspection/replacement of the protective anticorrosion anode, must be carried out by the
authorised maintenance service provider.
BUILDING-IN
The water heater shall be built in according to the drawing and table with dimensions in
a premise where there is no frost, as close as possible to the water outlets.
With regard to the needs, you can chose execution above the sink (TEG 0520 O/A;
TEG 1020 O/A) or an execution under the sink (TEG 0520 U/A; TEG 1020 U/A).
TECHNICAL PROPERTIES OF THE APPLIANCE
Type
Model
Volume
Weight / Filled with water
Connection power
Voltage
Heating time to 75°C
Quantity of mixed water by 40°C [ l ]
Energy consumption
1) Time for heating of the whole volume of heater with electric immersion heater by entering
temperature of cold water from water supply 10°C.
2) Energy consumption to maintain stable temperature of water in the water heater 65°C at
surrounding temperature 20°C, measured according to DIN 44532.
16
[ l ]
[ kg ]
[ W ]
[ V ~ ]
[ min ]
1)
2)
[ kWh/24h ]
TEG 0520 O/A TEG 0520 U/A
TEG 5 O
TEG 5 U
5
3,5/8,5
11
9,1
9,1
0,32
0,32
TEG 1020 O/A
TEG 1020 U/A
TEG 10 O
TEG 10 U
10
4/14
2000
230
22
17,2
0,50
16,4
0,52