Preparation
Before you Begin
Tools and Parts Needed
Parts Included
27" Appliances
General Information
Power Requirements
Dimensions for 27" Wall-Mounted Units
26
3/4"
(680mm)
29
1/16"
(738mm)
22
"
(559mm)
•
Phillips head screwdriver
•
Measuring tape
•
Drill with bit (1/8")
•
Phillips head screws (6)
The outlet must be properly grounded in accordance with all applicable codes.
24
"
(610mm)
28
1/4"
(718mm)
24
13/16"
(630mm)
27
"
(686mm)
min. 4
max. 31
7/8"
23
(606mm)
1/2"
25
(648mm)
3/4"
(121mm)
3/8"
(797mm)
Single Oven 27"
It is good practice, when oven is
installed at the end of a cabinet run,
adjacent to a perpendicular wall or
cabinet door, to allow at least 1/4"
space between the side of the oven and
the wall/door.
For oven support, install 2x4's
extending front to back flush with the
bottom and the side of the opening. The
supporting base must be well secured
to the floor/cabinet and level.
Note: The conduit box must be installed
either above or below the unit. If the
conduit box is installed below the unit, a
2" diameter hole or space is required
between the back wall and the right rear
of the 2x4 supports.
The cabinet base must be flat and
capable of supporting a weight of at
least 210 lbs (95 kg).
English 3