Télécharger Imprimer la page

ADEUNIS ARF868 Serie Mode D'emploi page 53

Publicité

Les langues disponibles

Les langues disponibles

ARF868 Radio Modems- Guide utilisateur / User guide version V2.2.2
Register
S212
Input character in command mode :
S214
0 : Disabling entry into command mode by UART.
0: Internal switches positions
S215
RTS/CTS UART flow control:
S216
Transmission start-up Timeout :
S217
1 à 6000 : timeout by step of 1 ms
Transmission start-up threshold :
S218
S220
0 : Asynchronous paquetized non secured
S222
2: Asynchronous paquetized secured
3: Continuous Asynchronous
4: Continuous Asynchronous «legacy X3Pro»
S230
1 : Exit «RSSI frame» on UART
4 : Exit «permanent RSSI» on UART
S231
Command mode entry Timeout at 9.6kbps at product start-up.
S241
Re-emitting time out (when S222=2)
S243
Adjustable from 0 to 65535 by step of 1ms
S250
1 à 65535 : Guard time by step of 1 ms
S252
Content
UART parity :
0: No parity
1: Parity
2: Odd parity
ASCII code (except 0)
UART interface:
1: RS232
2: RS485, no Term mode
3: RS485, Term mode
4: Auto
0 : Inactive
1 : Active
0 : no timeout
From 1 to 1024 octets
Communication mode
0 : Transparent
1 : Addressed
Radio protocol
RSSI mode:
0 : no RSSI
RF radiated power:
0 : 27 dbm
1 : 25 dbm
2 : 23 dbm
3 : 20 dbm
4 : 17 dbm
5 : 14 dbm
6 : 10 dbm
0 : disabled
1 : enabled
Repeater mode :
0 : no repeater
Source address (or local)
from : 1 to 65535
Default value
0
The input code is 3 times the character :
Example : +++ if the character programmed in S214 is
43
the ASCII code of «+» wether 43
Value between 1 and 255
Unless special request, the position of the internal switch
1
is on modem ARF868: Auto mode (same as S215 = 4). See
0
If #0, transmission starts when the timeout has passed, if
3
the threshold of the S218 register is not reached.
The transmission starts when the number of bytes in FIFO
30
memory to reach this threshold.
0
3
0
0 : on ARF7940
and 7941 ver-
sions
5 : on ARF7942
and ARF7943
versions
1
0
0
Factory pre-ini-
Used in the addressed mode. This register contains the
tialized
Comments
note 2
See note 3
See note 5
See note 5
address of the modem
Page
FR
EN
53
of of 58

Publicité