Télécharger Imprimer la page

ADEUNIS ARF868 Serie Mode D'emploi page 41

Publicité

Les langues disponibles

Les langues disponibles

ARF868 Radio Modems- Guide utilisateur / User guide version V2.2.2
1.9.1 Dimensions
1.9.2 Positioning of the modems
Install the modem at a minimum height of 2m and not against the face, ideally offset by 20 cm (5 to 10 cm minimum).
The RS232 cable should not exceed 15m in length and must be shielded.
1.9.3 Positioning of the aerial
In the event of use of a modem fitted with a TNC base for a remote aerial, we recommend using our range of aerials (Cf catalogue of
Stand-alone products available on our web site,).
The aerial should be installed in a free field, at least 10 cm away from any conducting material. There should be no metal obstacle within a
range of less than one metre.
Install the 2 aerials in view of each other.
If the modem is installed in an electrical cabinet, the aerial should be installed outside. The same applies if the modem is placed inside a
100cm
Antenna
building and it needs to communicate with a modem positioned outside.
The co-axial cable should be as short as possible (memo: cable of 25m => 6db of attenuation => range divided by 2)
1.9.4 Positioning of power and serial cables
To ensure optimal operation of ARF868 modems, it is essential to ensure that the power and serial communication cables are properly connec-
ted and positioned.
Improper positioning of the cables can significantly reduce the performance of modems.
The cables must be securely attached to the modem
The cables must be kept away from the antenna
The cables should not be coiled or tangled
20cm
FR
EN
100cm
Antenna
Page
41
of of 58

Publicité

loading