ARF868 Radio Modems- Guide utilisateur / User guide version V2.2.2
Command
Description
+++
Allows entry into command mode
ATO
Exit command mode
5.2. AT Commandes
A command starts with the two ASCII characters: "AT", followed by one or more characters and data (see C below for the syntax of AT com-
mands available on the modem).
Each command should end with a "CR" or "CR" "LF", the two possibilities are accepted. (CR signifies: Carriage Return, LF signifies: Line Feed)
On receipt of a command the modem returns:
"the data"<cr><lf>, for a reading command, type ATS<n> ? , AT/S or AT/V.
"O" <cr><lf>, for all other types of commands if it is accepted.
"E" <cr><lf>, if it refuses the command because of a syntax error, unknown command, unknown register, invalid parameter, etc.
"W"<cr><lf>, if it refuses the command because the configuration requested is not authorised.
"CM" <cr><lf>, if it accepts entry into the command mode
Table of AT commands:
Command
Description
ATS<n> ?
Returns the contents of register n
Transfer the value m to register n
ATS<n>=<m>
AT/S
Display as a list, the content of each User register
AT/V
Display the firmware version
ATR
Restore the content of registers with default values.
This command must be followed by an AT&W
command and a module reset to ensure that all
parameters have been applied.
ATT00
Enables test mode: Sends a predefined frame (see
note1).
Exit test mode ATT00 : ESC (0x1B)
ATT01
Enables test mode: Reception and control
frames received in opposite to ATT00 (see note1).
Exit test mode ATT01: ESC (0x1B)
ATT02
Starts the Scan Free mode
ATT03 <c> <t>
Scan of channel «c», during a «t» period , with :
-
-
ATX3
Automatic registers programming for X3Pro modems
compatibility :
-
-
-
-
Other registers to their default values.
AT&W
Save the register configuration in E2PROM.
AT&RST
Restart the modem
AT0
Exit command mode
Example of a series of commands and corresponding replies as one could see them on a terminal:
<c> value on three digits.
<t> value from 1 to 999, by step of 1s
S210 = 3 -> 9600 bauds
S215 = 1 -> RS232
S220 = 1 -> Addressed
S252 = 0 -> Source address = 0
Answer
« CM » to confirm entry in command mode.
«O»<cr> if operation OK
«E»<cr> if error
Reply
Sn=y where y represents the contents of register n
«O»<cr> if operation OK
«E»<cr> if error
« W» if the operation has a configuration problem.
Sxxx=y<cr><lf> for each register
Example : TW_AB_2.3.00_AA_B_1.2.0
«O»<cr> if operation OK
«E»<cr> if error
«O»<cr> if operation OK
«E»<cr> if error
«O»<cr> if operation OK
«E»<cr> if error
«Returns for each channel, its number and RSSI value associated :
Cxxx=-090dBm<cr><lf>
The command returns three values of RSSI: mini, medium and maximum.
«O»<cr> if operation OK
«E»<cr> if error
«O»<cr> if operation OK
«E»<cr> if error
«O»<cr> if operation OK
«E»<cr> if error
«O»<cr> if operation OK
«E»<cr> if error