5. Installation/Commissioning
Transformer connection
This product can only be installed by a qualified electrician.
The connection lines in the building must be disconnected before installation and secured against being
switched back on. For this, trip the corresponding fuse switch in the building installation.
Make sure that the surface is suitable for permanently and reliably taking the weight of the product.
No connect the connection lines of the primary and secondary sides with the respective terminals. The
brown (or black) cable is generally the phase conductor - connect this to the terminal marked with "L".
The blue conductor must be connected to the terminal marked with "N".
Important: All connection points must display a protection rating of min. IP67.
Do not bend the cables; make sure that the cables are not subject to tension or torsional forces.
Protect all cables and insulation against possible damages.
Check proper connection once again.
Switch the building installation's fuse switch back on.