6.
Faults
In order to ensure unit safety and leak
tightness, only approved persons may
open the units and replace parts subject
to water pressure.
Help with faults:
Fault
Cartridge becomes turbid!
Hairline cracks on the Car-
tridge!
Phosphate has run out.
Phosphate cartridge is leaky
after inserting.
Phosphate cartridge does
not de-aerate.
All manuals and user guides at all-guides.com
Cause
Cartridge has been
exposed to high tempe-
ratures or solvents.
Phosphate cartridge is
empty.
O-ring might be seized.
Water flow is too low.
JUDO EASY DOS
Faults
Remedy
Inform the fitter or nearest
customer service centre.
(Cartridge must be replaced
immediately.)
Insert a new phosphate
cartridge.
Check if the o-ring at the
phosphate cartridge fits
correctly.
Increase the water flow to
1000-2000 l/h or manually fill
the cartridge with water.
11