MAN-NT-16000-SYM-C01-F
PROBLÈMES ET SOLUTIONS
N°
PROBLÈMES
L'UNITÉ
HYDRAULIQUE
1
NE FONCTIONNE
PAS
L'UNITÉ
HYDRAULIQUE
FONCTIONNE,
2
MAIS LE PONT
ÉLÉVATEUR NE
MONTE PAS
LES BRAS DE
LEVAGE SONT
3
DÉSYNCHRO-
NISÉS.
LE PONT
ÉLÉVATEUR
4
DESCEND SANS
TOUCHER AUX
COMMANDES
CAUSES
1.
L
'
E MOTEUR N
EST PAS BRANCHÉ AVEC LE
(220
VOLTAGE REQUIS
VOLTS OU
2.
L
'
E MOTEUR DE L
UNITÉ HYDRAULIQUE N
:
ALIMENTÉ
2.1 L
.
E FUSIBLE EST BRÛLÉ
2.2 L
.
E DISJONCTEUR EST OUVERT
3.
L'
INTERRUPTEUR
MARCHE
.
DÉFECTUEUX
4.
L
'
E MOTEUR DE L
UNITÉ HYDRAULIQUE EST
.
DÉFECTUEUX
5.
L'
INTERRUPTEUR DE FIN DE COURSE EST
.
DÉFECTUEUX OU BRISÉ
6.
L'
INTERRUPTEUR DE FIN DE COURSE EST DÉPLACÉ
.
DE SON SOCLE
7.
L
'
:
E MOTEUR NE S
ARRÊTE PAS
7.1 L'
INTERRUPTEUR
MARCHE
.
DÉFECTUEUX
7.2 L
'
E RELAIS DE L
INTERRUPTEUR EST DÉFECTUEUX
8.
L
-
.
E COUPE
CIRCUIT EST FERMÉ
1.
L
3
E
MOTEUR
À
PHASES
HYDRAULIQUE NE TOURNE PAS DANS LE BON
(575
).
SENS
VOLTS
2.
L
A VALVE DE DESCENTE ET
ANTIRETOUR
NE
SONT
.
CORRECTEMENT
3.
L
A CHARGE DE LEVAGE EST TROP ÉLEVÉE
4.
L
E MOTEUR FONCTIONNE CORRECTEMENT
'
.
LA POMPE NE S
AMORCE PAS
1.
D
ÉSAJUSTEMENT
2.
L
A VALVE DE NIVELAGE SITUÉE SUR LA COLONNE
'
MAITRE N
EST PAS FERMÉE CORRECTEMENT
3.
L
ES BRAS DE LEVAGES SONT DÉFORMÉS
4.
L
ES BRAS DE LEVAGE ESCLAVE ARRIVENT AU SOL
AVANT CEUX DU CÔTÉ MAITRE
1.
L
A VALVE DE DESCENTE ET
ANTIRETOUR NE SONT PAS ÉTANCHES
2.
L
'
A VALVE DE NIVELAGE N
EST PAS FERMÉE
.
CORRECTEMENT
220 VOLTS ET 575 VOLTS
1.
D
EMANDER À UN ÉLECTRICIEN CERTIFIÉ DE BRANCHER L
575
).
VOLTS
LE COURANT REQUIS
'
EST PAS
2.1 R
EMPLACER LE OU LES FUSIBLE
2.2 R
ÉARMER LE DISJONCTEUR SUR LA COLONNE MAITRE ET
ÉLECTRIQUE
/
3.
D
ARRÊT
EST
EMANDER À UN ÉLECTRICIEN CERTIFIÉ DE REMPLACER L
/
MARCHE
ARRÊT
4.
D
EMANDER À UN ÉLECTRICIEN CERTIFIÉ DE VALIDER LA DÉFECTUOSITÉ
5.
R
EMPLACER L
6.
R
EPLACER L
M
ETTRE IMMÉDIATEMENT LE DISJONCTEUR EN POSITION ARRÊT
/
7.1 R
ARRÊT
EST
EMPLACER L
220 VOLTS
M
ETTRE IMMÉDIATEMENT LE DISJONCTEUR EN POSITION ARRÊT
.
7.2 R
EMPLACER L
8.
M
ETTRE LE COUPE
'
DE
L
UNITÉ
1.
D
EMANDER À UN ÉLECTRICIEN CERTIFIÉ DE VALIDER LA DÉFECTUOSITÉ
/
2.1 N
OU LA VALVE
ETTOYER LA VALVE DE DESCENTE ET
S
PAS
FERMÉES
I LE PROBLÈME PERSISTE
2.2 R
EMPLACER LA VALVE DE DESCENTE ET
3.1 V
ÉRIFIER LA CHARGE TOTALE DU VÉHICULE
.
3.2 D
IMINUER LE POIDS
RESPECTER LA CAPACITÉ DE CHARGE DU PONT ÉLÉVATEUR
4.1 V
ÉRIFIER LE NIVEAU D
,
MAIS
SONT AU SOL
S
I LE PROBLÈME PERSISTE
4.2 R
EMPLACER L
1. V
OIR SECTION
.
LEVAGE
2.1 F
ERMER LA VALVE DE NIVELAGE ET AJUSTER LES BRAS DE LEVAGE
INSTRUCTIONS D'INSTALLATION – A
S
I LE PROBLÈME PERSISTE
.
2.2 R
EMPLACER LA VALVE DE NIVELAGE DÉFECTUEUSE
2.3 C
OMMUNIQUER AVEC LE MANUFACTURIER DU PONT ÉLÉVATEUR
3. V
ANNEXE 3 – D
OIR
4.1 O
UVRIR LA VALVE DE NIVELAGE
4.2 A
CTIVER L
MÊME HAUTEUR QUE LES BRAS DE LEVAGE MAITRE
4.3 F
ERMER LA VALVE DE NIVELAGE
NOTE :
CONTACTER LE MANUFACTURIER SI LE VÉHICULE NE PEUT ÊTRE DESCENDU AU SOL
1.1 N
ETTOYER LA VALVE DE DESCENTE ET
/
OU LA VALVE
S
I LE PROBLÈME PERSISTE
.
1.2 R
EMPLACER LA VALVE DE DESCENTE ET
2.1F
ERMER LA VALVE DE NIVELAGE
S
I LE PROBLÈME PERSISTE
2.2R
EMPLACER LA VALVE DE NIVELAGE DÉFECTUEUSE
2.3 C
OMMUNIQUER AVEC LE MANUFACTURIER DU PONT ÉLÉVATEUR
SOLUTIONS
.
(
)
.
S
DÉFECTUEUX
.
.
'
INTERRUPTEUR DE FIN DE COURSE
'
INTERRUPTEUR DE FIN DE COURSE DANS SON SOCLE
'
.
INTERRUPTEUR DÉFECTUEUX
'
.
INTERRUPTEUR DÉFECTUEUX
-
CIRCUIT EN POSITION DE MARCHE
/
OU LA VALVE ANTIRETOUR
;
/
OU ANTIRETOUR DÉFECTUEUSE
.
(
,
COFFRE À OUTILS
CHARGEMENT
'
HUILE DANS LE RÉSERVOIR LORSQUE LES BRAS DE LEVAGE
. A
'
JOUTER DE L
HUILE AU BESOIN
;
'
UNITÉ HYDRAULIQUE DÉFECTUEUSE
INSTRUCTIONS D'INSTALLATION – A
JUSTEMENT DES BRAS DE LEVAGE
;
ÉFORMATION ACCEPTABLE DES BRAS DE LEVAGE
,
'
UNITÉ HYDRAULIQUE POUR SOULEVER LES BRAS DE LEVAGE ESCLAVE À LA
.
/
OU LA VALVE ANTIRETOUR
;
/
OU ANTIRETOUR DÉFECTUEUSE
.
;
RÉVISION: 2023-02-28
'
UNITÉ HYDRAULIQUE AVEC
/
OU AU PANNEAU
'
INTERRUPTEUR
.
.
.
:
.
.
.
.
,
.)
ETC
DU VÉHICULE POUR
.
(1"
).
DU BOUCHON AÉRATEUR
.
JUSTEMENT DES BRAS DE
. V
OIR SECTION
.
.
.
.
.
.
.
.
.
.
26 |
P
A G E