STARTING THE UNIT 
Make certain the generator is on a flat, level 
surface. 
2. Disconnect all electrical loads from the 
generator. Never start or stop the generator 
with electrical devices plugged in or turned on. 
Disconnect electrical devices 
 
 
 
3. Connect LPG tube to the LPG tank, and then 
open the LPG valve slowly, till it totally open (to 
insure no LPG leakage). 
4. Move the choke lever to the "Choke" 
position. 
5. Press the denser bottom of the REDUCTOR 
ASSY and hold 1~2 seconds; 
6. Pull the starter cord slowly until resistance is 
felt and then pull rapidly 
Recoil starting rope
 
 
 
7. As engine warms up, move the choke lever to 
"Run". 
CONNECTING ELECTRICAL LOADS AND 
ELECTRICAL CAPACITY  
After starting the generator, let the engine 
warm up after connecting electrical loads to it. 
Do not have any electrical loads connected 
before starting the generator. 
Make sure all electrical devices are 60 Hz 
devices.  
 
Do not connect 50 Hz devices to the generator. 
Do not connect 3‐phase loads to the generator. 
Do not overload the generator.  
Before beginning your work, you must verify 
that the rated (running) and surge (starting) 
watts for the items you will power at the same 
time are within the generators operating 
capacity. Please refer to the following Table 1 
for wattage / amperage ratings. Also, to prolong 
the life of your generator, prolong the life of 
your generator, sequentially add loads and 
permit the generator to stabilize before adding 
another load. Never exceed the capacity of the 
generator.  
Estimate how many surge (starting) watts you 
will need. Surge wattage is the short burst of 
power needed to start electric motor‐driven 
tools or appliances such as a circular saw or 
refrigerator.  
Stopping the Engine 
1.Turn off and unplug all electrical loads. Never 
start or stop the generator with electrical 
devices plugged in or turned on. 
 
 
 
 
2.Let the generator run at no‐load for several 
minutes to stabilize internal temperatures of the 
engine and generator. 
3. Turn the ignition switch to the "Off" position. 
 
 
 
 
4.Turn the fuel valve to the "Off" position. 
 
 
 
 