The use of other than genuine Powerforce by Ingersoll- - Rand replacement parts may result in safety hazards, decreased
tool performance, and increased maintenance, and may invalidate all warranties.
Repairs should be made only by an authorized Powerforce Servicenter. Call toll free 1 (866) 207-6923.
WARNING
Always wear eye protection
when operating or perform-
ing maintenance on this tool.
OPERATIONAL AND MAINTENANCE INSTRUCTIONS
90 psig maximum at tool inlet.
Lubrication - - Inject approximately 1.5 cc of
Powerforce No. 50 Oil into the air inlet before
starting the tool and after each two or three hours
of operation, unless the air line lubricator is used.
Lubricate with 1.5 cc of Powerforce No. 50 Oil
before storage.
Periodically, inject several drops of Powerforce No.
50 Oil into the Ratchet Head.
Forward/Reverse Operation - - Turn the
forward/reverse dial (14) counter clockwise to
tighten a nut. Turn the forward/reverse dial (14)
clockwise to loosen a nut. If the threads are
left- - handed, reverse the procedure.
Problem
Low speed or tool will not function
Low speed or tool will not function
Low speed or tool will not function
Low speed or tool will not function
Low speed or tool will not function
Ratchet head will not loosen nut or
mechanism slips
Low speed or tool will not function
Free Speed
Model
Model
rpm
rpm
PF705
260
260
PF775
H Tested in accordance with PNEUROP PN8NTC1.2
z Tested to ISO8662- - 7
All manuals and user guides at all-guides.com
WARNING SYMBOL IDENTIFICATION
Read this manual before
operating tool.
TROUBLESHOOTING
Possible Cause
Lack of lubrication
Low pressure
Low pressure
System leakage
Debris build up in tool
Torque of nut exceeds ratchet
capabilities
Worn mechanism
SPECIFICATIONS
Recommended Torque
Drive
in.
in
Ft- - lb
3/8"
5 to 24
5 to 24
1/4"
WARNING
Main Line(s) Inner Ø
to be 3X Size of
Air Tool's Inlet Ø
To Air
System
To Air
Tool
L
Emergency
Shut--Off
Valve
Lubricator
Regulator
Drain Regularly
Action
Add 1.5 cc of Powerforce oil #50 to
the tool
Ensure system regulators are set
properly to have 90 psi (6.2 bar/
620 kPa) at the tool inlet.
Ensure proper hose size. Long
hose lengths may require a hose
with a 1/2" ID or larger
Ensure connections are tight and
hoses are not damaged
Flush tool with 1.5 cc of
Powerforce oil #50
Hand tool with long lever arm or an
impact wrench (PF800) might be
needed to loosen nut
Replace ratchet head
(PF705--RHK1 or PF775--RHK1)
H Sound Level
Range
Nm
Pressure
7 to 32
7 to 32
92.2
92 2
2
WARNING
Always wear hearing
protection when operating
this tool.
Branch Line(s) Inner Ø
to be 2X Size of
Air Tool's Inlet Ø
R
F
Filter
FRL
Compressor
(Dwg. TPD905- -2)
z Vibrations
dB (A)
Level
Power
m/s
105 2
105.2
5.4
5 4
2