WIRING
Note: This range hood must be properly
grounded. The unit should be installed by a
qualified electrician in accordance with all
applicable national and local electrical codes.
1. Remove the grille to gain acces to inside of
the Range Hood.
2. Remove the wiring box cover. Remove a
knockout from the wiring box.
3. Feed 6" of power cable through the knockout
opening and secure cable to the wiring box
with an appropriate connector.
4. Make electrical connections. Connect white
to white, black to black and green to green.
5. Replace wiring box cover and screws. Make
sure that wires are not pinched between
cover and box.
CONNECT DUCTWORK
1. Use 8" round metal duct to connect the
duct connector on the hood to the ductwork
above.
2. Use duct tape to make all joints secure and
air tight.