12.3.2
CM721- Category 2: System Settings
Parameter
Parameter
No.
Minimum boiler
1:Ot
ON time
Cycle Rate
2:Cr
Pump Exercise
5:PE
System
6:Sn
Synchronisation
Loss of
7:LC
Communications
Instruction
Note
1) Remember to always press the green button to confirm that you want to store your new Installer Set-Up
setting. To exit the Installer Mode press the AUTO or MAN button.
12.3.3
Using the room thermostat for specific applications
Specific Application
Heating
Gas Boiler (<30kW)
Oil Boiler
Thermal Actuator
Zone Valve
All manuals and user guides at all-guides.com
Factory Default Setting
Display
Description
1
1 minute minimum ON
time
6
6 cycles per hour (cph)
0
Pump exercise
disabled
0
Standard operation of
the Room Unit
0
Relay Off
Setting
Cycle/Hour
Minimum ON Time
6
3
12
6
41
Installation, service and operating instruction
Optional Setting
Display
Description
2 to 5
Selection of 2, 3, 4 or 5
minutes minimum ON time
3,9 or
Selection of 3, 9 or 12 cph
12
1
Pump exercise enabled
1
Room unit configured as
Synchroniser
1
Relay 20% on / 80% off
What to change
Note: All parameters listed below
belong to category 2 - System
Parameters
1
No changes required
4
Set 1:Ot parameter to 4
Set 2:Cr parameter to 3
1
Set 2:Cr parameter to 12
1
No changes required
Alfa Laval Micro