Einbauanleitung
Mounting instruction
Montagehandleiding
Instructions de montage
Istruzioni di montaggio
Use:
- The Limit shower system can be shortened by the processor as
shown in Fig. 3.
- The kind of utilization of the shower space (splash protection, move-
ment area, etc.) is to be considered.
- For the installation of the shower system a level, clean, solid sur-
face free of vibrations and suited for fastening with Poresta
Flex must be available.
- The correct fitting of the discharge element is to be checked.
- The shower system is generally accessible for wheel chairs when
using tiles of a minimum size of 100 x 100 mm. If glass fabric is
worked into the tile adhesive bed, also tiles of a minimum size of
50 x 50 mm may be used.
- Suitable only for use indoor.
The relevant processing guidelines of all trades must be
observed.
For installation substructure elements (not included in supply,
1
see figs. 7a to 9a) or a cast screed base (see figs. 7b to
9b) are to be used. The height of the substructure element/
screed base is to be selected according to the difference in
height between the raw floor and the room flooring (see also
installation examples).
Edge insulation strips are to be provided locally.
2
Apply Poresta
Profi Flex to both sides.
®
3
The drain fitting must possibly be lined with suitable sound
4
absorbing material.
After the installation of the drain fitting, a leakage test must
5
be carried out.
Drain pipes must be sound-insulated.
6
The processing instructions of the Poresta
7
observed.
Adjustment of height to the tile floor using the supplied height
8
adapter.
Example for installation with Poresta
Mounting height/finished floor level
Poresta
Profi
®
2 layers of Poresta
Poresta
Installation example with screed base (Y):
Mounting height/finished floor level
Poresta
1 layer of Poresta
Screed base (Y)
The shower system Poresta
materials of construction material class B2 according to DIN 4102-1 (normally inflam-
mable) of class E according to DIN EN 1350-1 in installed condition.
KMK are to be
®
The design grating has a stainless steel surface and a tile
9
pan.
Limit
®
Profi Flex
®
UBE substructure element (X)
®
Limit
®
Profi Flex
®
Limit meets the requirements relating to the construction
®
Poresta
Limit
®
UBE substructure element (X):
®
140 mm
- 50 mm
-10 mm
= 70 mm
140 mm
- 50 mm
- 5 mm
= 85 mm
9 / 13