Télécharger Imprimer la page

Facom 712 Notice D'instructions page 16

Masquer les pouces Voir aussi pour 712:

Publicité

Les langues disponibles

Les langues disponibles

All manuals and user guides at all-guides.com
Measuring AC or DC Voltages
Set the selector switch to the voltmeter function
Place the contact tips in parallel on the circuit to be measured.
Range switching and AC/DC selection are automatic.
In V DC, the display indicates :
In V AC, the display indicates :
In V AC, an audible repetitive beeping indicates that the measurement voltage
is greater than the normative safety voltage to assure user protection, that is, 30
V AC (45 V DC or peak) (V-Live function).
Display Range
Measurement
0,20 - 39,99 V
Range
Precision
1% ± 5 points
Resolution
Input Impedance
16
.
V
OL
OL
OL
V
40,0 - 399,9 V
1% ± 2 points
10 mV
0,1 V
MΩ
(Voltmeter)
___
above + 600 V
___ below - 600 V
above 900 V peak
V
V
400 - 600 V DC
400 - 900 V AC
1% ± 2 points
1 V