Button Combinations
Modifying the «BEEP» threshold in continuity function : Press and hold the
yellow button and set the selector switch from the
The Ω value may then be set from 1 Ω to 40 Ω by successively pressing the yellow
button.
Once the value has been selected, actuate the selector switch to store it.
Disabling automatic turn-off : Press and hold the
selector switch from the
OFF
Disabling the V-Live function : Press and hold the
selector switch from the
OFF
Displaying the last calibration date : Press and hold the
and set the selector switch from the
Displaying the internal software version : Press and hold the
and set the selector switch from the
displays for 2 seconds and then all the display's segments turn on.
Setting the default configuration : Press and hold the yellow button and
set the selector switch from the
Default configuration :
Reading the Display
The concerned symbol turns on when the function is active :
Battery discharged
PEAK
In
and
function in
V
A
MAX
Indicates a maximum value in
MIN
Indicates a minimum value in
HOLD
The last value is stored
AC
The current measurement is made in AC (flashes when the clamp has
automatically selected the measurement mode, and is fixed if the
mode is manually selected)
DC
The current measurement is made in DC (flashes when clamping has
automatically selected the measurement mode, and is fixed if the
mode is manually selected)
+ or -
Indicates the polarity in DC and readout of the PEAK value
Semiconductor test
T° INT
T° position of the selector switch, or if the thermocouple probe
connected to the terminals is cut off or not connected (internal temperature measurement)
T° EXT
T° position of the selector switch, and when the thermocouple probe
is correctly connected
The tester is in permanent operation (disabling automatic turn-off)
Fixed : when the continuity function is selected.
Flashing : when the
Connections to the Tester
Place the black wire connecting tip in the terminal marked
Place the red wire connecting tip in the terminal marked «+».
position to Ω. . . . .
OFF
position to Ω. . . . .
position to
. . . . .
V
position to
. . . . .
OFF
V
position to
OFF
position to
.
OFF
A
BEEP threshold : 40 Ω
Automatic turn-off
With V-Live function
With temperature unit : °C
mode when the
MIN/MAX
mode
MIN/MAX
mode
MIN/MAX
function is selected.
V-Live
button and set the
HOLD
button and set the
HOLD
button
MIN/MAX
button
HOLD
. The software version
A
value is desired
PEAK
«COM».
15

Publicité

loading

Ce manuel est également adapté pour:

Nu-712/1200