Owner's Manual
Pump does not
function
Unit collects too
little water
If the problem you are experiencing is not listed here, call your local distributor or
contact the
Dri-Eaz Service Department toll-free at 800-932- 3030.
1.11 Specifications
Model
Type
Water removal AHAM (80°F/60%
RH)
Water removal max. (90°F/90% RH)
Max process air
Use weight
Dimensions
(H × D × W)
Amps (80°F/60% RH | 26.7°C/60%
RH)
Input Current (104°F/35%RH | 40°
C/35%RH
Power
Refrigerant
Max. use altitude
Operating range
Max. Oper. Temp.
DrizAir 1200 Owner's Manual108998K
Stuck float valve
Room air is dry.
Room temperature
is too low.
DrizAir 1200
#104677 (F203-A)
Standard refrigerant
64 pts. | 30 liters / day
125 pts. | 59.1 liters / day
250 CFM | 425 CMH
80 lbs. | 36 kg
32 × 20 × 19.5 in.
83 × 50 × 50 cm
5.3A
6.3A
6.4 amps, 115 volts
R32, 0.241 kg (8.5 oz)
10,000 ft. | 3 km
33°–100°F | 1°–38°C
104°F | 40°C
Clean float valve shaft.
Check humidity with hygrometer.
Increase room temperature.
Check filter and coils; clean as
necessary.
© 2023 Legend Brands, Inc.
15