FPS1000 SAFETY INSTRUCTIONS
SAFETY APPROVALS
UL 60950-1 and CSA22.2 No.60950-1 - UL Recognized. C-UL for Canada.
IEC 60950-1 - CB Report and Certificate.
EN 60950-1 - CE mark.
Marking by the CE Symbol indicates compliance to the Low Voltage Directive of the European Union.
A "Declaration of Conformity" in accordance with the preceding directives and standards has been made and is on file at our EU
representative TDK LAMBDA UK, located at Kingsley Avenue, Ilfracombe, Devon EX34 8ES, UK.
A "Declaration of Conformity" may be accessed via company website www.uk.tdk-lambda.com/technical-data
CAUTION:
The following safety precaution must be observed during all phases of operation, service and repair of this equipment.
Failure to comply with the safety precautions or warnings in this document violates safety standards of design, manufacture and
intended use of this equipment and may impair the built-in protections within. TDK Lambda shall not be liable for user's failure to
comply with these requirements.
Vorsicht:
Die folgenden Sicherheitsvorschriften müssen vor Inbetriebnahme und in jedem Betriebszustand bei Service oder
Reparatur beachtet werden. Missachtung der Sicherheitsvorschriften und Warnhinweise aus diesem Handbuch führen zur
Verletzung der bestehenden Sicherheitsstandards. Bei Betrieb des Gerätes ausserhalb dem bestimmungsgemässen Einsatz
können die im Gerät integrierten Schutzfunktionen beeinträchtigt werden. TDK-Lambda ist nicht haftbar für Schäden, die durch
Missachtung dieser Sicherheitsvorschriften entstehen können.
CAUTION: FPS1000 units are not authorized for use as critical component in nuclear control systems, life support systems or
equipment for use in hazardous environments without the express written approval of the managing director of TDK-Lambda.
Vorsicht:
Dieses Produkt ist nicht für die Verwendung als kritische Komponente in nuklearen Steuerungssystemen,
lebenserhaltenden Systemen oder Geräte für den Einsatz in gefährlichen Umgebungen, ohne die ausdrückliche schriftliche
Genehmigung durch TDK-Lambda zugelassen.
INSTALLATION (OVERVOLTAGE) CATEGORY& ENVIRONMENTAL CONDITIONS
The FPS1000 units have been evaluated to Overvoltage category II.
The FPS1000 units intended for use in the following operation conditions:
* Indoor use * Pollution degree 2 * Max. operational altitude: 3000m above sea level
*Ambient temperature: -10°C-50°C at 100% load, up to 70°C with output de-rating applied (See Specification)
GROUNDING
FPS1000 units are Class I product. To minimize electrical shock hazard, the FPS1000 units must be connected to an electrical ground.
The instruments must be connected to the AC power supply mains through a three conductor power cable, with the ground wire
firmly connected to an electrical ground (safety ground) at the power outlet. For instruments designed to be hard-wired to the supply
mains, the protective earth terminal must be connected to the safety electrical ground before any other connection is made. Any
interruption of the protective ground conductor or disconnection of the protective earth terminal will cause a potential shock hazard
that might cause personal injury.
Erdungskonzept:
Dieses Produkt ist ein Gerät der Schutzklasse 1. Zur Vermeidung von gefährlichen Energieinhalten und
Spannungen, ist das Gehäuse an eine Schutzerde anzuschliessen. Der PE-Anschluss ist an einen festen Erder anzuschliessen. Bei
Festverdrahtung des Gerätes ist sicherzustellen, dass der PE Anschluss als erstes angeklemmt wird Jede mögliche Unterbrechung
des PE-Leiters oder Trennung der PE Verbindung kann einen möglichen elektrischen Schlag hervorrufen, der Personenschäden zur
Folge hätte.
LIVE CIRCUITS
Operating personnel must not remove the FPS1000 units cover. No internal adjustment or component replacement is allowed by non-
TDK Lambda qualified service personnel. Never replace components with power cable connected. To avoid injuries, always disconnect
power, discharge circuits and remove external voltage sources before touching components. Restricted Access Area: FPS1000 units
should only be installed in a Restricted Access Area. Access should be available to service personnel only
Spannungsführende Teile
Die Geräteabdeckung darf nicht durch Endanwender geöffnet werden. Interne Modifikationen, sowie Bauteileaustausch ist nur
durch TDK-Lambda qualifiziertes Personal erlaubt. Vor Austausch von Bauteilen ist das Netzkabel bzw. die Versorgungsspannung
zu trennen. Energieversorgungsanschlüsse sind immer zu trennen, um Personenschäden durch gefährliche Energieinhalte und
Spannungen auszuschliessen. Die Stromkreise sind zu entladen, externe Spannungsquellen sind zu entfernen, bevor auf Bauteile bzw.
Komponenten Ebene gearbeitet wird.