SET GAS PRESSURE:
Gas pressure regulator is factory set.
SET PILOT FLAME:
1. The pilot adjustments are located between the control valves for each set of burners. The right
valve controls the front pilot; the left valve controls the rear pilot.
2. Using a small, flat-blade screwdriver, turn the screw clockwise to decrease the flame size, or
counter-clockwise to increase the flame size.
3. Adjust the pilot flame to 1/4" high. Test for operation: inside and outside sections of the burner
must light without undue delay.
4. Drafty conditions may require a higher flame to allow the pilot to remain lit.
ADJUST BURNER FLAME:
1. Remove all burner control knobs, and then remove the front panel.
2. Turn an individual burner on. The right knob controls the front burner; the left knob controls the
rear burner.
3. Loosen the locking screw on the shutter.
4. Turn the shutter to admit more or less air as required. Adjust the air shutter until the flame is
mostly blue in color.
5. Tighten the locking screw when finished. Replace the front panel and all knobs before returning
the unit to service.