Connection of the hob
For the various kinds of connection, use the brass bridges which are in the box next the terminal
Monophase 230V~1P+N
st
Put the 1
bridge between terminal L1 and L2, the 2
N2.
Attach the earth to the terminal "earth", the neutral N to terminal N1 or N2, the Phase L to one of
the terminals L1, L2 or L3.
Biphase
400V~2P+N
Put a bridge between terminal L1 and L2, the 2
Attach the earth to the terminal "earth", the neutral N to terminal N1 or N2, the Phase L1 to the
terminals L1 and the Phase L2 to the terminal L3.
Triphase
400V~3P+N
Put a bridge between terminal N1 and N2.
Attach the earth to the terminal "earth", the neutral N to terminal N1 or N2, the Phase L1 to the
terminals L1, the Phase L2 to the terminal L2 and the Phase L3 to the terminal L3.
Frequent loosening and screwing of the screws on the connection box risks damaging the
efficiency of the tightness once screwed. It is therefore advisable to keep screwing and
unscrewing to a minimum.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
equipped with a faulty earth connection.
nd
between L2 and L3, the 3
nd
between N1 and N2.
48
rd
between N1 and