Télécharger Imprimer la page

Wellell Optima Auto Link Mode D'emploi page 27

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 86
Optima Auto Link / English
Guidance and Manufacturer's Declaration- Electromagnetic Immunity:
This device is intended for use in the electromagnetic environment specified below. The user of this
device should make sure it is used in such an environment.
Immunity Test Levels
Basic EMC
Professional
standard
healthcare
facility environment
Electrostatic
±8 kV contact
Discharge (ESD)
± 2, 4, 8, 15 kV air
IEC61000-4-2
Electrical fast
±2 kV, 100 kHz for power supply line
transient/ burst
±1 kV, 100 kHz for input/output line
IEC61000-4-4
Surge
± 0.5, 1 kV (line to line)
IEC61000-4-5
± 0.5, 1, 2 kV (line to earth)
Voltage dips, short
Voltage Dips:
interruptions and
i) 100% reduction for 0.5 period,
voltage variations
ii) 100% reduction for 1 period,
on power supply
iii) 30% reduction for 25/30 period,
input lines
Voltage Interruptions:
IEC61000-4-11
100% reduction for 250/300 period
Power frequency
(50/60Hz)
30 A/m
magnetic field
IEC61000-4-8
3 Vrms
0,15 MHz – 80 MHz
Conducted RF
6 Vrms in ISM bands
IEC 61000-4-6
between 0,15 MHz
and 80 MHz
80 % AM at 1 kHz
Compliance
HOME
Levels
HEALTHCARE
ENVIRONMENT
±8 kV contact
± 2, 4, 8, 15
kV air
±2 kV, 100
kHz for
power
supply line
± 0.5, 1 kV
(line to line)
230 Vac
30 A/m
30 A/m
3 Vrms
3 Vrms
0,15 MHz – 80 MHz
0,15 MHz –
6 Vrms in ISM and
80 MHz
amateur radio
6 Vrms in ISM
bands between
and amateur
0,15 MHz and 80
radio bands
24
Electromagnetic
Environment-Guidance
Floors should be wood,
concrete or ceramic tile. If
floors are covered with
synthetic material, the
relative humidity should
be at least 30 %.
Mains power quality
should be that of atypical
commercial or hospital
environment
Mains power quality
should be that of atypical
commercial or hospital
environment.
Mains power quality
should be that of a typical
commercial or hospital
environment. If the user of
this device requires
continued operation
during power mains
interruptions, it is
recommended that the
device be powered from
an uninterruptible power
supply or a battery.
Power frequency magnetic
fields should be at levels
characteristic of a typical
location in a typical
commercial or hospital
environment.
Portable and mobile RF
communications
equipment should be
used no closer to any part
of this device, including
cables, than there

Publicité

loading

Produits Connexes pour Wellell Optima Auto Link