Télécharger Imprimer la page

AGA marvel MP15CL Instructions D'installation, D'utilisation Et D'entretien page 27

Machine à glacons transparente intégrées

Publicité

Les langues disponibles

Les langues disponibles

PREPARING THE ICE MACHINE FOR STORAGE
7. Disconnect the water valve's outlet water line to the
reservoir and drain the remaining water left in the water
line trap area. (See Figure 39 and Figure 39a).
Figure 39
To disconnect the water outlet
line: Push up on the white collar
and pull the plastic water line
from the bottom of the water
valve.
To reconnect the water outlet
line: Simply insert the plastic
tubing into the white collar and
push until it stops (about
mm, of water line will enter the
valve).
", 12
1
2
Figure 39a
Plastic outlet
water line
8. Reconnect the water valve outlet water line.
(See Figure 39 and Figure 39a).
9. Reinstall the ice machine's access cover.
10. Clean and dry the ice machine's storage bin.
11. Prop the door open for air circulation to prevent mold
and mildew.
12. Leave the water supply line disconnected or reconnect
the supply line and leave it shut off. Do NOT turn the
water on and allow water to enter back into the water
valve.
Draining Water for Factory Installed Drain
Pump Applications
Follow steps 1 through 12 for the gravity drain then do the
following:
13. Install the winterization plug in the water drain hole
inside the ice bin. (See Figure 40).
Winterization
White
collar
27
plug
Figure 40

Publicité

loading

Ce manuel est également adapté pour:

Mp15cp