GAS CONNECTION
Gas supply connections and any pipe joint compound must be resistant to the action of propane gases.
Location of the gas inlet is at the rear of the oven. Codes require that a gas shutoff valve must be installed
in the gas line ahead of the oven.
3
/
4
Prior to lighting, check all joints in the gas supply for leaks. Use soap and water
A. Check all joints prior to the gas valve (solenoid) before lighting unit.
B. Check all joints beyond gas valve (solenoid) after unit is lit.
After piping has been checked for leaks, all piping receiving gas should be fully purged to remove air.
TESTING THE GAS SUPPLY SYSTEM
disconnected from the gas supply piping system.
When gas supply pressure is
system by closing its individual manual shutoff valve.
BURNER AIR ADJUSTMENT
Although main burner air is adjusted before shipment, it should be checked at the time of installation.
GAS DATA
1
/
2
1
/
2