Télécharger Imprimer la page

Marklin Digital Link S88 Mode D'emploi page 18

Module de retosignalisation

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 24
Current Supply:
5 volts in mixed operation of S88 and S88 AC/DC Märklin products (as shown in the illustration), as well as products of other makes.
12 volts only in conjunction with the S88 AC/DC. The susceptibility to interruptions is reduced with a 12 volt power supply.
PIN Assignment for the RJ45 Plug
S88 Pin Name
Description
1
DATA
Readout Data
2
GND
Ground for signals and voltage supply
2
GND
3
CLOCK
Clock signal for the synchronization
4
PS (LOAD)
Load the data into the bus
5
RESET
Reset the input memory
6
+5V/+12V
Voltage supply for the feedback module
SHIELD
Cable shield, not connected
Märklin assumes no liability for joint use of Märklin products and products of other makes.
We therefore urgently recommend that you check the PIN assignments of the RJ45 plug you may be using.
All manuals and user guides at all-guides.com
Color
PIN RJ45
EIA/TIA 568A
2
green
3
white/ orange
5
white/blue
4
blue
6
orange
7
white/brown
1
white/green
15

Publicité

loading

Ce manuel est également adapté pour:

60883