d.- PRIO: input to activate/deactivate priority remotely. This input is in open circuit (priority deactivated),
you must close the circuit to activate the priority.
e.- Earth reference.
f.- EMER: audio signal input of an emergency system, together with the PRIO input, the emergency
message is clearly emitted. This audio signal shall not be affected by the output volume controls
of the power amplifier.
2.- OUTPUT SET: independent selector switch for each output channel to indicate the type of loudspeaker
output desired (70 V or 100 V).
3.- SPEAKER OUTPUTS: 4 output zones for the connection of high impedance loudspeakers (70 V or 100 V
depending on the OUTPUT SET selector). It is possible to connect 4 zones with 400 W power per zone
or 2 zones with 480 W RMS per zone (connect A or B, and C or D).
4.- Power supply input of the amplifier 115/230 V.
CONNECTION
IMPORTANT: it is important that the amplifier is properly cooled, so make sure that the place where it is
-
installed has access to air flow and that the chassis slots are free of obstacles.
-
With the power off, connect all audio and control sources.
-
Connect the loudspeakers to the corresponding outputs (CH A-D) and with the OUTPUT SET selector
indicate the type of output you want for each zone (70 V or 100 V).
*IMPORTANT: for proper operation and performance of the equipment, use the correct power, impedance
and frequency limits. Before connecting to other equipment, be aware of the conditions required in a
HIGH IMPEDANCE (100 V) installation.
More information can be found at:
-
Check that the volume controls are at minimum and connect the amplifier to the power supply.
-
Turn on the audio sources and other external equipment connected to the power amplifier first, and the
power amplifier last. Finally, adjust both volume controls.
4 CHANNELS
+
C
ZONE 1
ZONE 2
ZONE 3
ZONE 4
+
fonestar.com/downloads/install_fonestar_en.pdf
CH A, CH B,
CH C, CH D
100 V
OUTPUT SET
- +
-
CH
A
D
EMERGENCY
CH A & CH C
OUTPUT SET
- +
-
CH
C
D
FSD-4500E
CLASS-D POWER AMPLIFIER
4 x 400 W RMS
CH C
CH D
100 V
70 V
B C D
ZONE 4
max: 400 W RMS@100 V
ZONE 3
max: 400 W RMS@100 V
ZONE 2
max: 400 W RMS@100 V
ZONE 1
max: 400 W RMS@100 V
100 V
FSD-4500E
- 3 -
CLASS-D POWER AMPLIFIER
4 x 400 W RMS
CH C
CH D
100 V
70 V
A
B C D
~115 V AC. 50/60 Hz FUSE: T15AL 250 V
~230 V AC. 50/60 Hz FUSE: T10AL 250 V
POWER CONSUMPTION: 1,500 W
230 V AC
~115 V AC. 50/60 Hz FUSE: T15AL 250 V
~230 V AC. 50/60 Hz FUSE: T10AL 250 V
POWER CONSUMPTION: 1,500 W