DESCRIPTION
-
4-channel PA power amplifier.
-
100 V or 70 V output for PA installations.
-
Highly efficient and reliable class D amplifier thanks to low-maintenance protection circuits
-
Safe and easily connectable euroblock connectors.
-
Excellent sound quality and little noise.
CONTROLS AND FUNCTIONS
FRONT PANEL
POWER AMPLIFIER FSD-4500E
1
1.- On/Off switch of the stage.
2.- CLIP: signal peak indicator light for each input. If the indicator light comes on, it is because the input
signal is too high. To solve this problem, reduce the volume of the input signal.
3.- SIG: signal status indicator light. It lights up when a signal is detected at the outputs.
POWER AMPLIFIER FSD-4500E
4.- PROT: protection indicator light. It lights up when the temperature protection of the channel is activated.
When the protection is activated, the audio output of that channel is cut off. If this happens, turn off the
+
- +
C
D
equipment, make sure that the air intake and exhaust slots are free of obstacles and lower the volume
of the input signals. Wait a few minutes for the unit to stabilise before switching it on again.
POWER AMPLIFIER FSD-4500E
1
5.- Status indicator light.
1
- Green: the stage is on.
- Red: priority input active.
1
6.- CH A/CH B/CH C/CH D: volume controls for output channels CH A, CH B, CH C and CH D respectively.
REAR PANEL
+
- +
-
C
D
+
- +
-
C
D
1
1
1.- Euroblock connector.
a.- A/D: balanced audio inputs, each input will be played on the output channel named with the same
letter (input A on channel CH A and input B on channel B, etc). If the input signal is unbalanced,
the negative pole (-) will be free.
b.- FAIL: system failure indicator signal to monitor the equipment remotely. This output will remain at
5 V if the operation is normal and 0 V when a fault is detected (disabled/protection/inactive).
c.- DIS: input to enable/disable the stage remotely to make modifications to the wiring without having
to switch off the equipment from the front button. This input is in open circuit (stage enabled), the
circuit must be closed to disable the stage. When the stage is disabled, it is switched off, the LEDs
remain lit and the FAIL signal will go from 5 V to 0 V indicating a system fault.
4
CH A
CLIP
SIG
PROT
5
2
3
4
CH A
CLIP
OUTPUT SET
SIG
-
4
CH
A
B C D
PROT
CH A
2
CLIP
5
2
3
4
SIG
PROT
5
2
3
4
a
OUTPUT SET
CH
A
B C D
OUTPUT SET
CH
A
B C D
2
2
a
a
a
3
2
2 34
CH B
CH C
CH D
6
4
3
2
2 34
FSD-4500E
CH B
CH C
CLASS-D POWER AMPLIFIER
4 x 400 W RMS
CH C
CH D
100 V
70 V
3
2
2 34
CH B
CH C
CH D
3
6
6
+
- +
-
C
D
a
a
a
b c d
e
FSD-4500E
CLASS-D POWER AMPLIFIER
CH C
CH D
100 V
70 V
FSD-4500E
CLASS-D POWER AMPLIFIER
4 x 400 W RMS
CH C
CH D
100 V
70 V
3
3
+
- +
-
+
- +
-
C
D
C
D
a
a
b c d
e
a
a
a
b c d
- 2 -
CLIP
SIG
PROT
4
3
2
CH D
CLIP
~115 V AC. 50/60 Hz FUSE: T15AL 250 V
~230 V AC. 50/60 Hz FUSE: T10AL 250 V
SIG
POWER CONSUMPTION: 1,500 W
PROT
CLIP
4
3
SIG
PROT
4
3
2
f
4 x 400 W RMS
~115 V AC. 50/60 Hz FUSE: T15AL 250 V
~230 V AC. 50/60 Hz FUSE: T10AL 250 V
POWER CONSUMPTION: 1,500 W
f
e
f
4
2
~115 V AC. 50/60 Hz FUSE: T15AL 250 V
~230 V AC. 50/60 Hz FUSE: T10AL 250 V
POWER CONSUMPTION: 1,500 W
4
4