Electrical Requirements
Tumble dryers are supplied to operate at a
voltage of 220-240V, 50 Hz single phase. Check
that the supply circuit is rated to at least 6A.
Electricity can be extremely dangerous.
This appliance must be earthed.
The socket outlet and the plug on the
appliance must be of the same type.
Do not use multiple adapters and/or
extension leads.
The plug should be accessible for
disconnection after the appliance has been
installed.
CE Appliance complies with European Directive
2004/108/EC, 2006/95/EC and subsequent
amendments.
You may be charged for a service call if a
problem with your machine is caused by
incorrect installation.
If the mains cord on this appliance is
damaged, it must be replaced by a special cord
which is ONLY obtainable from the spares
service. It must be installed by a competent
person.
Do not plug the machine in and switch it
on at the mains until the installation is
completed.For your safety, this dryer must be
correctly installed. If there is any doubt about
installation, call GIAS Service for advice.
Adjusting the Feet
Once the machine is in
place the feet should
be adjusted to ensure
that the machine is
level.
All manuals and user guides at all-guides.com
Adequate ventilation must be provided in the
room where the tumble dryer is located to
prevent gases from appliances burning other
fuels, including open fires, being drawn into the
room during operation of the tumble dryer.
flue which is used for exhausting fumes from
appliances burning gas or other fuels.
the dryer is not restricted.
necessary.
The inlet and outlets should be kept free from
obstructions. To ensure adequate ventilation
the space between the bottom of the machine
and the floor must not be obstructed. There
should be a gap of at least 12mm between the
machine and any obstructions.
Prevent items from falling or collecting behind
the dryer as these may obstruct the air inlet and
outlet.
NEVER install the dryer up against curtains.
Important: During transport ensure that the
dryer is in an upright position, if it's necessary
you can only flip in the side shown;
Caution: If the product is in different side, wait
at least 4 hours before switching on so that the
oil can flow back into the compressor. Failure to
do this could result in damage to the
compressor.
INSTALLATION
VENTILATION
Exhaust air must not be discharged into a
Check regularly that the air flowing through
Check the fluff filter after use, and clean, if
Air Outlets in the Base