Installation Procedure
TURN OFF ELECTRIC POWER AT CIRCUIT BREAKER OR POWER SOURCE BEFORE MAKING ANY ELECTRIC
CONNECTIONS. GROUND CONNECTIONS MUST BE COMPLETED BEFORE MAKING LINE VOLTAGE CONNECTIONS.
Precautions for Electrical wiring
Electrical wiring work should be conducted only by authorized personnel.
Do not connect more than three wires to the terminal block. Always use round type crimped terminal lugs with insulated grip on
the ends of the wires.
Use copper conductor only.
Selection of size of power supply and interconnecting wires
Select wire sizes and circuit protection from table below. (This table shows 20 m length wires with less than 2% voltage drop.)
Item
Phase
Model
122, 182
242
Wiring connection
Make wiring to supply power to the outdoor unit, so that the power for the indoor unit is supplied by terminals.
AD182ALERA
AD242ALERA
AD242ALEAA
Make wiring to supply power to the indoor unit, so that the power for the outdoor unit is supplied by terminals.
AD122ALEAA
AD122ALERA
AD182ALEAA
DANGER OF BODILY INJURY OR DEATH
Circuit breaker
Switch breaker
Overcurrent protector
(A)
rated capacity (A)
1
40
1
40
Indoor unit
terminal block
Outdoor unit
L
N
terminal block
Power supply :1PH, 220-230V~, 50Hz
1
2
3
Outdoor unit
terminal block
1
2
3 N
Indoor unit
terminal block
Power supply:1PH, 220-230V~, 50Hz
WARNING
Power source
wire size
(minimum)
(mm
26
2.5
26
4.0
1
2
3 N
L
1
2
3
Y/G
Y/G
L
Y/G
25

Electrical wiring

Earth leakage breaker
Switch
Leak
breaker(A)
current(mA)
)
2
40
30
40
30
Y/G