LOCATION REQUIREMENTS

Place the air conditioner on a flat, level surface in a
location that is at least 20" (51 cm) from any wall.
NOTE: A minimum clearance of 20" (51 cm) from the
air conditioner to the wall must be maintained to
ensure proper airflow.
Maintain a minimum 20" (51 cm) clearance around the air
conditioner to not block airflow.
Keep the air conditioner free of any obstructions such as
drapes, curtains, blinds, etc.
The exhaust hose should be free of any obstructions.
Do not place the air conditioner on an unstable or raised
surface because it could fall and cause damage or injury.
Do not place the air conditioner in direct sunlight or near
a heat source such as baseboard heaters, stoves, etc.
The window panel can be installed in a window with a
minimum 20" (51 cm) to a maximum 40" (101.6 cm)
opening.
20"
(51 cm)

ELECTRICAL REQUIREMENTS

Remote
Control
Batteries (2)
Plug into a grounded 3 prong outlet.
Do not remove the ground prong from the power
cord plug.
Do not use an adapter.
Do not use an extension cord.
Failure to do so can result in death, fire or
electrical shock.
POWER SUPPLY CORD
Wiring Requirements
If this power supply cord is damaged, it cannot be repaired. It
must be replaced with a cord from the product manufacturer.
If the power supply cord is damaged call Haier Customer
Service: 1-877-337-3639.
20"
(51 cm)
To test the power supply cord before operation:
1.
2.
REQUIRED GROUNDING METHOD
This air conditioner must be grounded. The air conditioner is
equipped with a power supply cord that has a 3 prong
grounding plug. The power supply cord must be plugged into
a mating, grounded 3 prong outlet, and grounded in
accordance with all local codes and ordinances.
4
WARNING
Electrical Shock Hazard
115 Volt, 60Hz, 15-amp fused grounded 3 prong outlet
The use of a time-delay fuse or time-delay circuit breaker
is recommended.
Use a dedicated circuit only.
NOTE: Do not operate any other electrical
appliances on this circuit or you may trip the circuit
breaker/fuse.
RESET
Plug the power cord into a grounded 3 prong outlet.
Press the Test button, and then press and release the
Reset button to restore power.
TEST
115V
15 Amp