Recoverable
fault
Unrecoverable
fault
Artificial turned
off
Please refer to chapter 6 and 8 for detailed fault information and
Note
troubleshooting.
OPERATION PANEL
There are 4 buttons on the panel:
(1) "ESC", exit and return ;
(2) "
", back to the front page and data increasing;
(3) "
", to the next page and data decreasing;
(4) "ENT", enter.
The machine can be turned on and off by pressing the buttons: press "ESC" and
"ENT"(about 3 seconds) at the same time, and then the quick start-up and stop is
available.
LCD SCREEN
Inverter stand-by. The public grid fault(A001, A003,
Run
Warn
A004, A005or A006);
Fault
Yellow indicator blinks in every 0.5s, others off
Run
(1) Inverter stand-by. Temperature abnormal(E006);
Warn
(2) Inverter stand-by. DC input fault (E001);
Fault
Yellow indicator keeps on, others off
Hardware or software fault (E003, E004, E005, E008,
Run
E009, E011, E013 or E015). De-couple the inverter
Warn
Fault
from the system before maintenance.
Red indicator blinks in every 0.5s, others off
Current-leakage or unqualified output power energy of
the inverter (E007, E010, E014, E017, E018 or E020).
Run
Warn
De-couple the inverter from the system before
Fault
maintenance.
Red indicator keeps on, others off
Run
Stop after the communication or panel command. All
Warn
Fault
indicators are on.
Figure 17 Operation panel