395008
Maintenance Schedule
ITEM
REMARKS
Clean, adjust, replace if
Spark Plug
necessary
Check & adjust when
Valve Clearance
engine is cold
Carburettor
Check choke operation
Idle Speed
Check & adjust idle speed
Check for leakage, tighten
Exhaust System
or replace gasket if
necessary
Check exhaust baffle,
clean replace if necessary
Engine Oil
Check oil level
Replace oil
Air Filter
Fuel Filter
Clean fuel tap & tank filter
Inspect for cracks or
Fuel Line
damage, replace if
necessary
Cooling System
Check fan damage
Starting System
Check recoil starter
Check all fittings/
Fittings/
fasteners, tighten or
Fasteners
replace as necessary
• User Maintenance
Cleaning
• Only clean when Generator has fully cooled down.
• Use a mild soapy solution and a stiff brush.
• Rinse with clean water
• Dry as thoroughly as possible – parts of this product will corrode if
left wet.
• Only carry out maintenance when the Generator has fully cooled down.
• Maintenance should be adjusted according to use and environment.
Generally, the more use and harsh the environment, the more frequent
the maintenance.
Cleaning the Air filter element
• Remove the two screws at the top and bottom of the Air Filter Cover
(11) and gently pull the cover off.
• Remove Air Filter (11) noting which way around it faces.
• Wash the Air Filter in a suitable fluid (available from most garden
machinery retailers).
• Replace Air Filter by reversing this procedure.
All manuals and user guides at all-guides.com
BEFORE EACH
AFTER FIRST
USE
20 HRS USE
• Authorised Service Centre Only
www.silverlinetools.com
2.2 kVA Generator
EVERY 3
EVERY 6
MONTHS/
MONTHS/
50 HRS
100HRS
• Only After First 20hrs Use
Replacing and adjusting the spark plug
• Pull the ignition lead off the Spark Plug (16) Fig. C
• Unscrew the Spark Plug (16) using the socket supplied.
• Adjust the gap (see specification) using a feeler gauge. Clean using
a wire brush OR replace using a recommended Spark Plug (see
specification).
• Replace Spark Plug and tighten firmly with the socket and bar.
• NOTE: be careful not to cross or over tighten the threads.
• Refit ignition lead.
Changing the engine oil
• Start and run the engine for around 2 minutes to warm the oil, then
switch off.
• Place the Generator above a large oil draining bowl (Silverline tools
recommend product 675089) Make sure the Drain Plug (26) is above
the centre of the bowl.
• Using a 10mm socket and long extension, undo (anticlockwise) the
Drain Plug (26)
EVERY 12
MONTHS/
300HRS
9