2
A
INSTALLING THE PX2
1. Securely wall mount the PX2 at eye level outside
the growing environment, using the provided
screws and mounting holes.
2. Plug the power adapter into an outlet and connect
the other end to the PX2 power supply port (A –
see image above). Ensure threaded connection is
tight.
3. Plug the temperature probes into the
corresponding ports (B, D) and run your probe
cables their full length up to and across the ceiling,
toward the center of the grow space. Suspend the
probes above the plant canopy. Take care not to
stress or damage the probe cables when securing
them to walls and ceilings.
4. Connect the zone signal cables (C, E).
IMPORTANT: A bare probe receiving direct light from a fixture can cause premature dimming
and/or inaccurate temperature readings. When setting up the temperature probes, shield them
from exposure to direct light.