4.3 Noise information and vibration values in accordance with EN 60745
The sound pressure and vibration values given in these instructions were measured in accordance with a
standardized test and can be used to compare one power tool with another. They can also be used for a
preliminary assessment of exposure. The data given represents the main applications of the power tool.
However, if the power tool is used for different applications, with different accessory tools, or is poorly
maintained, the data can vary. This can significantly increase exposure over the total working period. An
accurate estimation of exposure should also take into account the times when the tool is switched off, or
when it is running but not actually being used for a job. This can significantly reduce exposure over the
total working period. Identify additional safety measures to protect the operator from the effects of noise
and/or vibration, for example: Maintaining the power tool and accessory tools, keeping the hands warm,
organization of work patterns.
Noise information
Typical A-weighted emission sound pressure level (L
Typical A-weighted sound power level (L
Uncertainty
Vibration information
Triaxial vibration value
Uncertainty (K)
5 Operation
5.1 Preparations at the workplace
CAUTION
Risk of injury! Inadvertent starting of the product.
▶ Unplug the supply cord before making adjustments to the power tool or before changing
accessories.
Observe the safety instructions and warnings in this documentation and on the product.
5.1.1 Adjusting the guard
1. Set the device on the work surface.
2. Release the clamping lever.
3. Turn the retaining ring with lamellar seal until the gap between lamellar seal and work surface is correct.
4. Turn the guard to the desired position.
5. Close the clamping lever.
Note
If the guard is not secure when the lever is in the closed position, tighten the clamping band by
turning the adjusting screw clockwise with a screwdriver.
If the guard is too tight to move when the lever is in the open position, slacken the clamping band
by turning the adjusting screw counter-clockwise with a screwdriver.
5.1.2 Adjusting the guard for working close to an edge
1. Release the clamping lever.
2. Turn the top part of the guard relative to the bottom part until the desired position is reached.
3. Set the device on the work surface.
4. Turn the retaining ring with lamellar seal until the gap between lamellar seal and work surface is correct.
5. Close the clamping lever.
Note
More dust can escape past the guard when the device is used for working close to an edge.
5.1.3 Adjusting the side handle
1. Slacken the side handle by turning the securing screw counter-clockwise.
Printed: 28.11.2017 | Doc-Nr: PUB / 5069653 / 000 / 04
)
pA
)
WA
88 dB(A)
99 dB(A)
3 dB
5.8 m/s²
1.5 m/s²
English