Option 1: Power supply using the power-supply unit (mains adaptor)
Two insulated wires are required to power the device by connecting it to the
power-supply unit (mains adaptor) supplied with it. These wires are normally
already there and are freely accessible once you have removed the previous
door chime. You can also connect the power supply without any additional
wires to the door chime, the power supply has a 300cm long cable with two
insulated wires. If you need longer wiring, connect the wires of the power
supply using the supplied crimp connectors with the two wires that you want
to use for the power supply.
Do not plug the power supply unit into the wall socket yet.
N OTICE
Only use the power supply unit provided along with the device, or a
DIN-rail power supply unit that you can obtain from us separately,
since this has been specially stabilized electrically and is equipped
with an integrated audio interference reduction device. Other power
supply units may destroy the device or cause poor transmission quality.
The warranty automatically expires if you use a different power supply
unit. The power supply unit is plugged into a wall socket inside your
house, usually where the two wires from your previous door chime
comes out of the wall in the interior of the house.
Option 2: Power supply via PoE (as an alternative)
To power the device via a PoE-Switch (e.g. D-Link DGS-1008P) or PoE-Injector
(e.g. DoorBird Gigabit PoE Injector) in accordance with the PoE standard IEEE
802.3af Mode A, the four wires bearing the numbers 1, 2, 3 and 6 of a Cat.5
cable or better are to be used. A Cat.5 cable or better must be used as network
signals can only be transmitted over completely insulated, shielded and
twisted cables. If you use PoE as a source of power, the WiFi interface of the
device is automatically inactive, and the four wires for PoE then simultaneously
form the data link. The device won't start if your PoE Switch or PoE injector
does not support the PoE Standard IEEE 802.3af Mode A (see Diagnostic-LED
and Diagnostic-Sounds).
1. Disconnect the PoE-Switch or PoE-Injector from the power grid.
2. Place the network cable in the installation site of the device.
Do not combine the power supply from the power supply unit
N OTICE
(mains adaptor) with the power supply via PoE. You can find further
information about PoE here: http://www.doorbird.com/poe
STEP 6: FURTHER CONNECTIONS (OPTIONAL)
If desired, connect additional wires to the installation site of the device.
The wires or connection options mentioned in this section are optional.
11