Télécharger Imprimer la page

MAUNAWAI PICIONNECT Peka Manuel De Montage Et D'utilisation page 9

Publicité

Les langues disponibles

Les langues disponibles

sCOPE Of dELIvErY
Before assembling MAUNAWAI®
Peka, please check with the help
Case
Filter cartridge
2 ball valves
1 wall bracket per housing
One set of 4 stainless steel
screws per enclosure for attach-
ing the wall bracket to the housing
(screws and wall plugs for the wall
are not included) and
16
of the illustration whether all com-
ponents are present.
6
2x 1
1/2"
| 1" double reducing
nipples for connection to the ball
valves
6
1 housing key for opening/clos-
ing the housings
7
Option:
Includes 1" double nipples for link-
ing two or more cases
INsTaLLaTION
aNd COmmIssIONINg
Work on the drinking water pipe
must be carried out by a specialist
plumber.
Local regulations, general guide-
lines (e.g. WVU, EVU, VDE, ÖVE,
DIN, DVHW, ÖVGW, SVGW), the
technical data and installation and
safety regulations must be ob-
served.
We draw particular attention to
the necessary earthing of the wa-
ter pipe (potential equalisation).
The use of a pressure reducer is
recommended.
Please note that the max. pressure
load of the Peka housing is 4.5 bar
continuous load.
In the case of a municipal domestic
water connection, a system sep-
arator up to FK-4 in accordance
with DIN EN 1717/DIN 1988.100
must be installed upstream of the
filter system, if prescribed.
Ask your installer about this.
The Peka modules are installed
in the drinking water pipe down-
stream of the water meter and any
house filter using the screw con-
nections supplied.
If the existing pipe size differs from
the connection size of the fitting,
the transition must be made with
an additional commercially availa-
ble sleeve made of brass or stain-
less steel.
For optimal operation, ensure that
the additional weight of the Peka
module is supported by existing
suitable or additional pipe sup-
ports.
en