7
8
9
20
Let water into the mains by ope-
ning the main valve behind the
water meter.
Open the small vent valve on the
housing cover and let the air es-
cape until the water appears. The
vent valve can now be closed.
Now open the valve on the other
side of the connection block (out-
let side).
Continue to bleed the line if neces-
sary. (See point 7)
Check whether all connections of
the assembly are tight. To do this,
rub the connection spots dry from
below with a dry cloth and wait a
few minutes.
If the spots remain dry, the sys-
tem is ready for operation.
maINTENaNCE
The filter cartridges should be re-
placed regularly, depending on the
water quality, according to the re-
placement intervals.
The replacement is simple and can
be carried out by yourself with the
supplied housing key and the enc-
losed instructions.
ChaNgE INTErvaLs
basic filter:
approx. 12 Monate
Intensive filter:
approx. 12 Monate
Limescale filter:
approx. 3–5 Jahre
PI filter:
5 Jahre
WarraNTY
MAUNAWAI
GmbH
provides
24-month warranty for the compo-
nents/modules if they are installed
correctly.
Our customer service must be gi-
ven the opportunity to rectify or
replace the product.
Note
Only suitable for cold water ope-
ration!
Do you have any further questi-
ons?
Write us an
E-mail: info@maunawai.com
or give us a call.
a
en
21