. LP gas tank must be arranged for vapor withdrawal.
. It is essential to keep the outdoor appliance's valve compartment,
burners,and circulating air passages clean. Inspect outdoor appliance before
each use. This outdoor appliance should be thoroughly cleaned and inspected
on a regular basis. Clean and inspect the hose before each use of the
appliance. If there is evidence of abrasion, wear, cuts, or leaks, the hose must
be replaced prior to the appliance being put into operation.
. LP Tank used must include a collar to protect the cylinder valve
. The LP gas tank must have a listed overfilling prevention device (OPD) and a
QCCI or Type I(CGA791) LP gas tank connection.
. The LP gas tank should not be dropped or handled roughly.
. Tanks must be stored outdoors out of the reach of children. Do NOT store in
a building, garage, or any other enclosed area.
. Never store your LP gas tank where temperatures can reach over 125°F.
. Never keep a filled LP gas tank in a hot car or car trunk. Heat will cause the
gas pressure to increase, which may open the valve and allow gas to escape.
. Place dust cap on valve out let whenever the LP gas tank is not in use. Only
install the type of dust cap on the LP gas tank valve outlet that is provided with
the LP gas tank valve. Other types of caps or plugs may result in leakage of
propane.
. Do not store a spare LP gas tank under or near this gas appliance.
. Never fill the tank beyond 80 percent full.
. LP gas cylinders should only be filled by a certified LP gas dealer.
. The pressure regulator is set for 11 inches of water column (pressure).
. Any guard or other protective device removed for servicing the appliance
must be replaced prior to operating the appliance.
. Installation and repair should be done by a qualified service person. The
appliance should be inspected before use and at least annually by a qualified
service person. More frequent cleaning may be required as necessary. It is
imperative that control compartment, burners and circulating air passage ways
of the appliance be kept clean.
. The appliance should be inspected before use and at least annually by a
qualified service person.
. Do not attempt to disconnect the gas regulator from the tank or any gas
fitting while the outdoor appliance is in use.
. Keep gas appliance away from location where it can get excessively wet. Do
not use gas appliance if any part has been underwater.
Immediately call a qualified service technician to inspect the appliance and to
replace any part of the control system and any gas control which has been
under water.
10
. This appliance shall be used only outdoors in a well-ventilated space and
shall not be used in a building, garage or any other enclosed area.
. The LP-gas supply cylinder must be disconnected when this appliance is
not in use
. Only cylinder marked "propane" shall be used.
Be sure to use only one 20lb(9.1kg) LP gas cylinder with a Type 1valve with
this appliance as required by the American Nation Standards Institute(ANSI)
and the Canadian Standards Steering Committee.
. Never attempt to attach this appliance to the self-contained LP gas system
of a camper trailer, motorhome or house.
. Hand turn the manual gas control valve. Never use tools. If the valve will
not turn by hand, do not try to repair it. Call a Certified Gas Technician. The
use of force or any self attempted repair may result in a fire or explosion.
. WARNING: Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Refer to the owner's
information manual provided with this appliance. For assistance or additional
information consult a qualified installer.
LP Hose and Regulator Assembly and Replacement
1. This appliance comes equipped with a standard LP gas hose and
regulator including the appliance side connection for a CGA No 791 Cylinder
Connection Device. The LP gas hose and regulator supplied with this
appliance must be used. Only a hose and regulator specified by
manufacturer can be used for replacement.
a) The CGA No791connectionincorporates an excess flow limiting device
that acts to limit the flow of gas if a leak is detected between the regulator
and the burner valve.
b) If the burner valve is open prior to the LP gas cylinder service valve being
opened, the connection will interpret this free flow of gas to be a leak.
c) The connection safety feature will reduce gas flow from the regulator to
the appliance to a minimal level.
d) Be sure that the burner control valve is closed prior to opening the LP gas
cylinder service valve to ensure that the connection flow limiting device is not
triggered mistakenly.
e) If the connection flow limiting device is triggered mistakenly, close the LP
gas cylinder service valve and the burner valve, wait 10 seconds to allow the
device to reset, open the cylinder service valve, then open the burner valve
and light the appliance as per lighting instructions.
2. Be sure to protect the hose from any hot surfaces. Serious danger may
result if the hose contacts any hot surface.
3. Regular maintenance of the hose and regulator:
a) Inspect the hose before each use of the appliance. If the hose shows