4. Technical specifications

Required power supply:
Supply voltage
Frequency
Current power
Environment:
Use
Temperature
Installation
Protection class

5. Commissioning

Warning:
-
Electrical installation must be carried out by a skilled electrical engineer according to
the applicable national and local regulations.
-
The equipment must be properly earthed. Earthing is required to ensure safe and
proper operation and to prevent electrical shocks upon contact.
-
Do not touch any live parts.
Otherwise you will receive a dangerous electric shock!
-
Disconnect the power supply before carrying out work on the unit.
-
Only use the generator in combination with suitable Simco-Ion bars/electrodes.
-
Keep the generator free of dirt, dust and moisture in order to ensure its safe
operation.
-
High voltage can be dangerous, especially to people with a pacemaker.
-
Do not use the CM5 in an environment where there is a risk of fire or explosion.
-
Do not expose the CM5 to vibrations and knocks.
-
The equipment may only be repaired by Simco-Ion employees.
-
Touching live parts of the charging bar/electrode will cause a dangerous electric
shock.
Note:
-
Use only the supplied fasteners to fix the bracket to the CM5 (M4x8 fastening screws).
-
Do not install the generator in a dirty or damp environment, or in an environment
where chemicals or other corrosive agents are handled.
-
Arrange the generator so that it is free from vibrations.
-
Refer to the full manual for additional instructions.
Position the generator in a clearly visible, easily accessible and stable location, on or close to
the machine, and as close as possible to the charging bar or electrode.
Note:
Earthing must be via the power cable and via the external earth wire to the earthing
-
point on the generator. Connect the external earth wire to an earthed machine part.
Connect the electrodes/charging bars to the HV output connector (see full manual, sections 5
and 5.5).
CM5_WithAnybus_QM_9752090130_NL_D_GB_F_IT_V2_0
100 – 240 V AC
50 – 60 Hz
Max. 240 W
Industrial, internal use
0 – 55°C
Dust-free and vibration-free
IP20
16