ATTENTION: All adjustments and modifications to be performed on the gas installation and
connection of the device should be performed by authorized people.
ADJUSTMENT ACCORDING TO DIFFERENT GAS TYPES
If the device is connected to gas installation, close main gas inlet valve.
Replacement of burner nozzles (fig. B)
1. Open the cabinet cover of the fryer. (7178.0510/7178.0515/7178.3045/7178.3050)
Unscrew the front panel (7178.0080/7178.0085)
Unscrew the nozzle (3) at the burner inlet using a suitable wrench.
2. Replace nozzle (3) with a nozzle suitable one for the gas type.
3. Adjust the pilot flame (1) by turning bolt nut (2)
The venturi (Gas/Air tube) adjust part gap should be 10 mm for LPG gas type, 20 mm
for NG gas type. ( Fig.1)
After adjust of venturi tube gap, tight with a suitable wrench.
D. OPERATOR INSTRUCTIONS AND ATTENTION POINTS
Before cooking with the fryer, operate it with no load (by pouring water in its chamber)
for a while. Thus, the protection oil on it will disappear and it will become ready to use.
When you do not cook, keep the adjustment button on pilot position. It will provide a
more economical usage for you.
Never operate the fryer without oil. Check whether the chambers are full with oil before
use.
When the oil level descends to minimum, refill oil.
If you will not use the device for a long time, cover it with suitable oil and keep away
from moisture.
Do not operate the device with its back funnel mouldings removed or closed.
Figure 1