Storage
•
Do not store in temperatures below -20°C or above +50°C or in an atmosphere with a relative humidity above 90%.
Store the mask in its original packaging or in a sealed container so that it is protected from sunlight and dust.
•
Pre-use checks
•
Read the user instructions for the device attached to the mask.
•
Make sure that the mask is not damaged.
Putting the mask on the face (Figure 2 – example for configuration with webbing attachment)
Place the neck strap on the back of your neck, with the mask lens turned down.
•
Place the chin in the lower part of the mask and pull the harness over your head.
•
•
Position the centre of the harness as far back on the head as possible and gradually tighten the harness, starting with the lower
straps and then the upper straps. Do not overtighten.
With the palm, cover the mask connector, breathe in and hold your breath. The mask should collapse onto face and remain so as
•
long as breath is held. This helps to make sure that an effective seal is achieved. If the mask goes back to its initial position before
you breathe out, adjust the strap again and repeat the test.
Removing the face mask (example for configuration with webbing attachment)
•
Push the buckle tabs forward with your thumbs to unfasten the harness.
Carefully pull the mask up over your head.
•
Cleaning instructions
•
Detach the breathing apparatus from the mask connector.
•
Wash the mask with a warm soap solution or the EPI-US product – P/N 1779065 aqueous solution of 3%. Do not use organic
solvents or abrasive products to clean the mask.
Rinse the mask thoroughly with clean running water.
•
•
Wipe the mask dry with a clean lint-free cloth and hang it by the neck strap in a well-ventilated place away from sunlight.
•
Once the mask is dry, clean the lens with a soft cotton cloth and ALTUSIL.
FREQUENCY OF MAINTENANCE AND INSPECTION OPERATIONS
Checking or maintenance operations must be carried out by technicians authorised by HONEYWELL RESPIRATORY
•
SAFETY PRODUCTS, having an inspection bench, special tools and original HONEYWELL RESPIRATORY SAFETY
PRODUCTS parts, as well as the maintenance procedures.
Any OPTI-PRO CL3+ mask exposed to strong radiant heat must be inspected. Check all the sensitive components such
•
as the visor, bottom, fasteners or fastening system, and their securing points, retaining strap etc.
Any OPTI-PRO CL3+ mask exposed to a blaze must be replaced.
•
Perform a monthly inspection of the mask to detect deteriorations, torn straps and faceblanks, split seals and valves. Do not use the
mask until worn or damaged parts have been replaced.
Operation
Cleaning, disinfection
Air-tightness test on inspection bench
Change of valve, Seals
LIST OF SPARE PARTS AND ACCESSORIES (figures 1a, 1b, 1c, 1d &
Ref
Fig
Description
Inhalation valve, pack of 20
60
1b
Opti-Pro visor
63
1b
Opti-Pro visor collar kit,
64
1b
pack of 5
Opti-Pro
65
1a
maintenance kit
Opti-Pro Air-Klic connector
66
1b
kit
Opti-Pro full-face connector
67
1b
Opti-Pro
full-face
68
1b
mask
Opti-Pro grilles, pack of 5
69
1b
Opti-Pro expiration valve kit
84
1b
All manuals and user guides at all-guides.com
Mask maintenance schedule
Code
1741080-
SP
1715089-
SP
1741084-
SP
general
1741062-
SP
1741085-
SP
1741086-
SP
inner
1741087-
SP
1741089-
SP
1741090-
SP
Mask in operation
Mask in storage
After each use
Every 12 months
Every 2 years
Every 6 years
1e)
Ref
Fig
Description
Neck straps for Opti-Pro 5-
62
1c
branch head harness and green
net, pack of 5
Set of 5-branch head harness
85
1c
for Opti-Pro
Opti-Pro
86
1c
harness kit
Opti-Pro
87
1d
harness kit
Pair of straps and hooks for KS
88
1d
head harness for F1 helmet
Opti-Pro KS neck straps, pack of
89
1d
5
90
1e
Opti-Pro full-face green net kit
91
1e
Opti-Pro green net
Allan key for Opti-Pro visor collar
Spectacle rims for mask
ALTUSIL oilcan (product for
cleaning visors)
EPI-US, 5 litre can
EN-2
-
-
Code
1741081-SP
1715099-SP
elastomer
head
1741088-SP
full-face
KS
head
1705301-SP
1705302-SP
1741083-SP
1705304-SP
1710313-SP
1715080-SP
1710150-SP
1779061
1779065