Télécharger Imprimer la page

LA NORDICA ROSSELLA PLUS Instructions Pour L'installation, L'utilisation Et L'entretien page 18

Publicité

Les langues disponibles

Les langues disponibles

4.
FIRE SAFETY
In the installation of the stove the following safety measures are to be followed:
a) In order to ensure sufficient thermal insulation, respect the minimum safety distance from objects or
furnishing components flammable and sensitive to heat (furniture, wood sheathings, fabrics. etc.) and
from materials with flammable structure (see Picture 2 - A). All the minimum safety distances are
shown on the product data plate and lower values must not be used.
b) in front of the chimney stove there must not be any flammable object or building material, sensitive to
heat, at less then 100 cm's. of distance. This distance can be reduced to 40 cm's if you will install in
front of the element to protect a retro ventilated and heat resistant protection.
c) If the product is installed on a non totally refractory floor, one must foresee a fireproof background. The
floors made of inflammable material, such as moquette, parquet or cork etc., must be replaced by
a layer of no-inflammable material, for instance ceramic, stone, glass or steel etc. (dimensions
according to regional law). In case the replacement of the floor is not possible, the appliance
shall be placed on a minimum 12 cm thick slab made of stone or concrete. The platform must
stick out 50 cm's in front and 30 cm's sideways (Picture 2 B).
d) no flammable components (e.g. wall units) must be present above the product.
The stove must work exclusively with inserted ash drawer.
Solid combustion residuals (ashes) must be collected in an air-tight and fire-resistant container. The device
must never be switched on when there are gaseous emissions or vapors (for example glue for linoleum,
gasoline etc.). Do not deposit flammable materials close to the stove.
During the combustion will be spread thermal energy which warms up the surfaces, the door, the fireplace
glass, the handles and knobs, the smoke pipe and the front side of the stove. Please avoid the contact of
these parts without gloves or the relevant tools.
Warn children of the danger and keep them away during the operation of the stove.
The use of a wrong or wet fuel causes the formation of creosote deposits in the flue and will fuel a chimney
fire.
4.1. FIRST-AID MEASURES
Should any fire arise in the stack or in the flue:
a) Close the feeding door and the ash drawer door.
b) Close the registers of combustion air
c) Extinguish the fire using carbon dioxide fire-fighting means (CO
Seek immediate intervention of FIRE BRIGADE.
d)
DO NOT EXTINGUISH FIRE USING WATER JETS
When the fire has been extinguished, let the flue check by an expert to find possible cracks and permeable
points.
18
Rossella Plus – Rossella Plus forno / Nicoletta – Nicoletta forno / Gisella
100
A
30
30
50
B
Picture 2
dust).
2
7192450 – EN

Publicité

loading

Ce manuel est également adapté pour:

Rossella plus fornoNicolettaNicoletta fornoGisella