Before installing the product check the following points: (1) the fan impeller turns freely and (2) there are no obstructions
to the airflow.
All models include a robust mounting bracket which enables easy and quick installation of the fan. See Figure (2) Instal-
lation
Diagrams For TD - MIXVENT Duct Fans.
Ductwork connection should be made with duct tape or duct fast-clamps (available through your local distributor) to en-
sure a good seal and secure connection.
ELECTRICAL CONNECTION
All TD - MIXVENT series fans operate from a standard 120V 60Hz A.C electrical supply. All wiring must be carried out in
accordance with National Electrical Code and all applicable state and local buildings codes.
Electrical connections should be made in accordance with the following diagrams: Figure (3) Electrical Wiring.
MAINTENANCE
IMPORTANT: BEFORE CARRYING OUT ANY MAINTENANCE OR SERVICING, ENSURE THE UNIT IS DISCON-
NECTED FROM THE MAIN ELECTRICAL SUPPLY.
All TD - MIXVENT series exhaust fans incorporate sealed for life bearings and therefore do not require any lubrication.
We would recommend inspection of the product at least once every twelve (12) months to avoid the excessive accumula-
tion of dust and dirt on the impeller. To inspect the unit disconnect from electrical supply and remove from ducting. If any
debris is evident on the impeller clean with a damp (not wet) cloth. DO NOT USE any detergents or abrasive materials
for cleaning.
WARRANTY
Soler & Palau USA - Soler & Palau Canada warrant that the TD - MIXVENT series exhaust fan will be free from defective
materials and workmanship for the period of (5) years from the date of original purchase. In the event that we find any
part is defective the product will be repaired or, in the Company's discretion, replaced without charge provided that the
product has been installed in accordance with the enclosed instructions and all applicable EPA Standards and state and
local building codes. Soler & Palau TD Bath Kits have an extended warrranty period of (7) years from the date of original
purchase.
IF CLAIMING UNDER WARRANTY
Please return the complete product, freight paid, to you local authorized distributor. All returns must be accompanied by
a valid Bill Of Sale. All returns must be clearly marked "Warranty Claim," with an accompanying description stating the
nature of the fault.
THE FOLLOWING WARRANTIES DO NO APPLY
Damages from shipping, either concealed or visible. Claim must be filed with the carrier.
Damages resulting from improper wiring or installation
Damages caused by acts of nature, or resulting from improper consumer procedures such as: Improper Maintenance;
Misuse; Negligence; Alteration; Abuse; Abnormal Use; or Accident or Incorrect Electrical Voltage and Current.
Removal or alteration to the Soler & Palau USA - Soler & Palau Canada data plate label.
WARRANTY VALIDATION
The end user must keep a copy of the Bill of Sale to verify purchase date.
THE ABOVE FIVE (5) YEAR WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED,
WRITTEN OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR USE. IN NO
EVENT SHALL SOLER & PALAU USA - SOLER & PALAU CANADA BE LIABLE FOR ANY SPECIAL, CONSEQUEN-
TIAL, OR INCIDENTAL DAMAGES, INCLUDING LOSS OF PROPERTY, REVENUES, LOST PROFITS, COSTS OF
REMOVAL, INSTALLATION OR REINSTALLATION.
6