Télécharger Imprimer la page

Atlas Copco ITB-A61-100-HAD Mode D'emploi page 3

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
ITB-A61-100-HAD
Technical Data
Product Data
Motor voltage
Motor power
Speed
Torque range
Weight
Product Power Source
This product can be used with either a battery, or with an
electrical power cable in combination with a power supply
unit.
Battery Compatibility
Accessory
Battery, 18V (2.5Ah)
Battery, 18V (2.5Ah)
Battery, 36V (2.5Ah)
Battery, 36V (2.5Ah)
Charger Temperatures
Charger operating tempera-
ture
Wireless LAN Information
Regulatory Do-
Band
main
ETSI
2.4 GHz
U-NII-1
U-NII-2
U-NII-2e
FCC/IC
2.4 GHz
U-NII-1
U-NII-2
U-NII-2e
U-NII-3
Charger Compatibility
Accessory
Flex charger
35 V d.c.
1500 W
280 r/min
20 - 100 Nm (15 - 80 ft lb)
3.1 kg (6.8 lb)
Article No.
4211 6030 85
4211 6130 06
4211 6030 86
4211 6130 14
+5 to +40 °C
(+41 to +104 °F)
TxChannels
1, 2, 3, 4, 5, 6, 7, 8,
9, 10, 11
36, 40, 44, 48
52, 56, 60, 64
100, 104, 108, 112,
116, 120, 124, 128,
132, 136, 140
1, 2, 3, 4, 5, 6, 7, 8,
9, 10, 11
36, 40, 44, 48
52, 56, 60, 64
100, 104, 108, 112,
116, 132, 136, 140
149, 153, 157, 161,
165
Article nr.
4211 6083 84
© Atlas Copco Industrial Technique AB - 9846 0253 00
EU SAR value
EU SAR Value: 0.55
Ambient Temperature
For best battery performance and life time, keep battery
within temperature intervals.
Operating temperature, charge
Operating temperature, discharge
Transportation temperature
Storage temperature
Do not place battery in direct sunlight.
Maximum Radio Output Power
Frequency Range
Radio Technology
(MHz)
Wi-Fi®
2402-2480
Wi-Fi®
5180-5320
Wi-Fi®
5500-5700
Bluetooth® wire-
2402-2480
less technology /
Bluetooth® Low
Energy
Wi-Fi® is a registered trademark of Wi-Fi Alliance®
The Bluetooth® word mark and logos are registered trade-
marks owned by Bluetooth SIG,Inc.
Declarations
Liability
Many events in the operating environment may affect the
tightening process and shall require a validation of results. In
compliance with applicable standards and/or regulations, we
hereby require you to check the installed torque and rotational
direction after any event that can influence the tightening re-
sult. Examples of such events include but are not limited to:
• initial installation of the tooling system
• change of part batch, bolt, screw batch, tool, software,
configuration or environment
• change of air- or electrical connections
• change in line ergonomics, process, quality procedures or
practices
• changing of operator
• any other change that influences the result of the tighten-
ing process
The check should:
Safety Information
+5 to +40 °C
(+41 to +104 °F)
0 to +40 °C
(+32 to +104 °F)
−20 to +40 °C
(−4 to +104 °F)
+10 to +25 °C
(+50 to +77 °F)
Maximum Trans-
mit Power EIRP
(dBm)
19.46
20.37
18.39
9.29
3

Publicité

loading